KIT CONTENTS

Please read these instructions completely before beginning installation

QTY.  DESCRIPTION

  1 

PWM Fan Controller

  1 

Sensor (Pre-wired to controller)

  1 

50 Amp Circuit Breaker

  6 

#10 Sheet Metal Screw

  1 

2ft 10 AWG Red Wire

  1 

Yellow Butt Connector

  2 

Yellow 5/16” Ring Terminal

  2 

Yellow #10 Ring Terminal

  2 

Blue Wire Tap Connector

  4 

4” Wire Ties

 

INSTALLATION INSTRUCTIONS

PWM ELECTRIC FAN CONTROLLER

PART # 16797

16797-InstructionSheet

(Page 1)

IMPORTANT NOTES

This fan controller has been completely quality control tested prior to final packaging.

MAXIMUM CAPACITY: 70 AMPS

This controller will operate multiple fans with a combined maximum amperage up to 70 amps. On dual fan applications, it is 
important to know your fan(s) amp draw before installing, if fan(s) exceed 70 amps, all warranty will be void.

AUTO RESETTING CIRCUIT BREAKER

The fan controller utilizes a 50 amp auto resetting circuit breaker to protect the fan(s) and controller circuit. In the event of an 
electrical issue, the breaker will “trip” and open the connection between the battery and the controller. The circuit breaker will 
automatically reset once the issue has been corrected. If installing fan(s) exceeding 50 amps in total you must use a fuse or 
circuit breaker suitable for your systems amp draw.

MAIN POWER CONNECTIONS

The positive and negative wires feeding the fan controller MUST be connected directly to the vehicles battery.

This is very important because the controller requires a clean signal, do not connect directly to the fuse panel, starter or the 
alternator. 

VEHICLES BATTERY LOCATION

If the vehicles battery is located more than 5 feet from the fan controller, the signal could encounter some interference or noise, 
which causes a dirty signal. In some cases, a larger 6 gauge wire may be required. Please contact our technical support team 
for more information. (323) 266-3850 or

 [email protected]

TEMP SENSOR

This unit is equipped with a newly released aluminum temp sensor that reacts 50% quicker than previous models. It uses 3M 
double stick tape to adhere right to the radiator tank, therefore getting a very accurate temperature reading. The surface 
preparation is critical; surface must be absolutely free of dirt, oil, peeling paint or any contaminants to ensure a proper bond.

Important:

  The ideal application temperature range is 70°F to 100°F (21°C to 38°C).The minimum suggested application 

temperature is 50°F (10°C). At 70°F approximately 50% of the ultimate bond strength will be achieved after 20 minutes, 90% 
after 24 hours and 100% after 72 hours.

OVERRIDE CIRCUIT

The fan controller has an override circuit (Green Wire) available that when activated, will ramp up the electric fans to 60% 
running speed. As the engine temperature increases the fans will increase accordingly.

WIRE CONNECTIONS

Crimp connections are critical to the function of this controller, please ensure that all connections are made using quality 
crimpers. After each crimp has been completed, tug wires, there should be no movement within the connector. Ground 
connectors are crucial. If grounding to chassis we do not recommend using self tapping screws as they tend to loosen 
over time.

COOL DOWN FUNCTION

This PWM fan controller is designed with a cool down function that will allow the electric fan(s) to run for 20 seconds after the 
vehicle has been turned off.

RevA-10-6-2021

TOOLS NEEDED

Drill
 5/32” Drill Bit
Multimeter / Test Light
Standard Screw Driver
5/16” Nut Driver
Standard Screw Driver
(1/8” wide blade)
Wire Stripper
Wire Crimping Tool

Summary of Contents for 16797

Page 1: ...gnal could encounter some interference or noise which causes a dirty signal In some cases a larger 6 gauge wire may be required Please contact our technical support team for more information 323 266 3850 or techsupport usmotorworks com TEMP SENSOR This unit is equipped with a newly released aluminum temp sensor that reacts 50 quicker than previous models It uses 3M double stick tape to adhere righ...

Page 2: ... ensure a proper bond The Ideal application temperature range is 70 F to 100 F 21 C to 38 C The Minimum suggested application temperature is 50 F 10 C At 70 F approximately 50 of ultimate bond strength will be achieved after 20 minutes 90 after 24 hours and 100 after 72 hours WIRING Before starting disconnect the negative cable on the vehicles battery Using the electrical connectors and wire ties ...

Page 3: ...to maintain fluid temperatures from 130 F 230 F Follow the directions below to make adjustments to the temperature 1 Remove the rubber plug from the side of the fan controller 2 Using a 1 8 blade screwdriver follow the instructions below If your engine is running too cool Turn the adjustment screw CLOCKWISE in increments of 2 FULL turns then test before repeating If your engine is running too hot ...

Page 4: ...etup Gray Low Speed Brown High Speed Yellow 10 Ring Terminal Fan s Fan s Q U I C K R E F E R E N C E G U I D E Yellow 10 Ring Terminal Outlet Inlet Sensor install option Fan s Connect the Negative wires on the electric fan s to a good chassis ground Connect the Blue Wire from the wire harness to the Positive Wire s of the Electric Fan s Radiator Sensor Placement Derale Performance PART 16797 Custo...

Page 5: ...ATTENTION If you have any technical questions about this controller please contact Derale Performance Phone 323 266 3850 Email techsupport usmotorworks com ...

Reviews: