![Deprag AST40-1 Operating Instruction Booklet Download Page 135](http://html1.mh-extra.com/html/deprag/ast40-1/ast40-1_operating-instruction-booklet_2485170135.webp)
135
15 Error display and troubleshooting
15.1 System error
If you discover that the AST40 sequence controller is defective, please send it to
DEPRAG. Please do not try to troubleshoot or rectify any electrical fault on your own under
any circumstances whatsoever.
15.1.1 MINIMAT–EC-Servo Screwdriver
Number Meaning
Trouble shooting
-- Screwdriver
not
found
Insure that the screwdriver and the connection
cable are properly attached before you switch on
the AST40.
001
Temperature too high
Check the screw assembly process and adjust if
required. If necessary please contact DEPRAG
Service.
002
Flash not found!
003
Error reading Flash file system
directory!
004
Access to protected Flash areas!
005
Defective parameter memory!
006
File not found!
007
Calibration file defective or not initiated!
008
Resolver signals too small!
009
Voltage supply outside of range!
010
5V supply outside of range!
011
Value outside of limits!
012
Incorrect number of available
measuring systems!
Troubleshooting not possible
Table 45:
System error MINIMAT–EC-Servo screwdriver
15.1.2 Power unit
Number Meaning
Trouble shooting
--
Power unit not found
Switch the AST40 off and then restart again. If
the fault remains, please contact the DEPRAG
Service Department.
101
Position indicator index signal not
found
102
QEP position indicator signal missing
or wrong
103
Initialization error, spindle free?
Ensure that the drive unit of the
EC-Servo screwdriver turns freely. Re-start
the AST40.
104
Condenser loading error, power unit
defective
105
External Watchdog or overcurrent error
Troubleshooting not possible
106
Temperature too high
Check the screw assembly and adjust it if
necessary.
If required, consult the DEPRAG Service
Department.
107 Area
error
108 Under
voltage
... Reserved
116 Error
flash
117
RAM error or set-up information /
adjusting values in flash not legible.
118
5V supply error
119
3.3V supply error
Troubleshooting not possible