DentalEZ Ramvac Installation Manual Download Page 1

INSTALLATION 

MANUAL

VACUUM TANK

Summary of Contents for Ramvac

Page 1: ...INSTALLATION MANUAL VACUUM TANK ...

Page 2: ... Connections 10 InfiniTank Switch 11 SECTION IV PLUMBING Drain and Waste Details 12 Drain Check Valve Installation 13 Vacuum Check Valve Installation 13 Tank Inlet Manifold for Multiple Tanks 14 Facility Vacuum Line from Operatories 14 Tank to Vacuum Power Unit Line 14 SECTION V AUTOWASH How the System Works 15 System Schematic 15 SECTION VI ACCESSORIES Tank Vacuum Platform 16 Tank 12 Height Exten...

Page 3: ...ii VACUUM TANK INSTALLATION MANUAL 866 DTE INFO dentalez com PN 7717 006A NOTES ...

Page 4: ...rson For bays let Rooms equal chairs 3 2 1 30 GALLON TANK 4 15 GALLON TANK 15 GALLON TANK 3 2 1 4 Connects to waste piping see SECTION IV PLUMBING DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Connects to Aeras control TANK FLOAT opt connector see SECTION I...

Page 5: ...V PLUMBING TANK TO VACUUM POWER UNIT LINE Connects to Aeras control INFINITANK SOLENOID opt connector see SECTION III AERAS CONTROL CONNECTIONS Connects to Aeras control TANK FLOAT opt connector see SECTION III AERAS CONTROL CONNECTIONS Tank inlet for 50 gallon tank is 3 Tank outlet for 50 gallon tank is 3 1 2 3 4 5 INFINITANK 50 GALLON CYLINDRICAL TANK Typical No of Treatment Rooms 1 20 13 20 Nom...

Page 6: ...FLOAT opt connector see SECTION III AERAS CONTROL CONNECTIONS 1 2 3 4 3 3 15 GALLON TANK WITH RV4 12 15 GALLON TANK WITH RV5 2 RV7 2 OR RV10 2 Typical No of Treatment Rooms 1 6 1 6 Nominal Width in 29 33 Nominal Depth in 19 21 22 RV10 2 Nominal Height in 48 59 Floor to Drain Centerline in 8 8 This assumes one chair per person For bays let Rooms equal chairs TANKS VACUUMS STACKED 15 GALLON TANK WIT...

Page 7: ...ooms equal chairs 30 GALLON TANK WITH RV5 2 RV7 2 OR RV10 2 2 INFINITANK WITH RV5 2 RV7 2 OR RV10 2 1 3 2 4 4 SECTION I SPECIFICATIONS 6 5 5 Connects to waste piping see SECTION IV PLUMBING DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Platform optional Con...

Page 8: ... SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Connects to vacuum unit located remotely see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Vacuum check valve see SECTION IV PLUMBING VACUUM CHECK VALVE INSTALLATION Suspension Hooks Remove tank legs Use leg bolts to attach and suspend tank from ceiling with chain or cable customer supplied Connects to Aeras control TANK FLOAT opt connector ...

Page 9: ...G DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Connects to Aeras control TANK FLOAT opt connector see SECTION III AERAS CONTROL CONNECTIONS Connects to Aeras control INFINITANK SOLENOID opt connector see SECTION III AERAS CONTROL CONNECTIONS 1 2 3 4 5 ...

Page 10: ...ects to waste piping see SECTION IV PLUMBING DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Connects to Aeras control INFINITANK SOLENOID opt connector see SECTION III AERAS CONTROL CONNECTIONS Connects to Aeras control TANK FLOAT opt connector see SECTION I...

Page 11: ...G DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Vacuum check valve see SECTION IV PLUMBING VACUUM CHECK VALVE INSTALLATION Tank inlet for 50 gallon tank is 3 Tank outlet for 50 gallon tank is 3 1 2 3 4 3 1 3 2 4 2 1 SECTION II INSTALLATION 1 2 4 3 ...

Page 12: ...UM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Tank locations 2 and 3 are reversible Sling kit for horizontal 50 gallon tank is Ramvac supplied Mounting hardware for custom tank is customer supplied Tank support requirements 1 gallon of liquid 8 33 lbs e g 50 gallon tank 8 33 lbs 416 5 lbs 1 2 3 ROTATE THE ELBOW AND PIPE ASSEMBLY TO CREATE T...

Page 13: ...OL CONNECTIONS InfiniTankTM solenoid optional Autowash optional Vacuum inHG kPa Motor temperature Pump temperature Oil level Tank float optional Water in oil Water in pump Ambient temperature humidity 1 2 3 4 5 6 7 8 9 10 AERAS CONTROL BOX SIDE VIEW AERAS CONTROL BOX FRONT VIEW 1 2 3 4 5 6 7 8 9 10 ...

Page 14: ...nk option press the gray INFINITANK switch The switch will turn green indicating that the InfiniTank option is now ON Pressing the green switch will turn the InfiniTank option OFF Press TECHNICAL to return to the previous screen Technical Advanced Infinitank Power Up Override Runtimes Sensors Motors Alerts Maintenance Mode 07 33 14 PM LTE Settings Technical Info Home Tandem Network Advanced ADVANCE...

Page 15: ... sizes larger than waste pipe Trap seal minimum 4 deep Vents Trap vent size no less than half the trap and drain branch size Vents no smaller than drain check valve Vents must extend a minimum of 6 above tank top before turning horizontally NOTICE Follow current NFPA 99c Edition Ramvac instructions and all local codes TRAP VENT WASTE PIPE FROM VACUUM TANK DRAIN TO SEWER TO SEWER MULTIPLE TANK SETU...

Page 16: ...onnecting couplers no gaps Flow toward sewer Fits 1 schedule 40 PVC Slide valve open FLOW HORIZONTAL USE UP NOTICE Slide valve is for service use only Leave in the open position OPEN Install vacuum check valve assembly with THIS SIDE UP facing up Pipes butted inside connecting couplers no gaps Flow toward vacuum unit Fits 2 schedule 40 PVC Isolates non operating vacuum units ...

Page 17: ...schedule 40 PVC with DMW fittings or equivalent Vacuum Models RV5 2 RV7 2 and RV10 2 2 or larger schedule 40 PVC with DMW fittings or equivalent All Vacuum Models Slope Minimum 1 4 per 10 feet If an in line low spot is unavoidable place it in a known location and incorporate a clean out For overhead plumbing contact Ramvac For nitrous oxide scavenging contact Ramvac TANK TO VACUUM POWER UNIT LINE ...

Page 18: ...vacuum system is turned on during that period the autowash process will immediately cease SYSTEM SCHEMATIC 1 3 2 4 5 6 Connects to waste piping see SECTION IV PLUMBING DRAIN AND WASTE DETAILS Connects to operatories see SECTION IV PLUMBING FACILITY VACUUM LINE FROM OPERATORIES Connects to vacuum unit see SECTION IV PLUMBING TANK TO VACUUM POWER UNIT LINE Facility water supply piping Connects to Ae...

Page 19: ...NFO dentalez com PN 7717 006A SECTION VI ACCESSORIES TANK VACUUM PLATFORM 30 GALLON TANK WITH PLATFORM AND RV5 2 RV7 2 OR RV10 2 VACUUM UNIT VACUUM UNIT PLATFORM 15 GALLON TANK WITH 12 EXTENDER STAND BRACE STAND EXTENSIONS TANK 12 HEIGHT EXTENDER ...

Page 20: ...17 TANK SUSPENSION HOOKS SECTION VI ACCESSORIES SUSPENSION HOOKS 4 CHAIN OR CABLE CUSTOMER SUPPLIED ...

Page 21: ...18 VACUUM TANK INSTALLATION MANUAL 866 DTE INFO dentalez com PN 7717 006A NOTES ...

Page 22: ...ing care or maintenance Damage resulting from the use of chemicals cleaners disinfectants or sterilization is not covered under this warranty nor is normal wear and tear Failure to follow or observe our operating use maintenance and or installation instructions voids this warranty as does installation or other work performed by anyone other than DENTALEZ or its authorized dealers the use of non au...

Page 23: ... Bay Minette AL 36507 T 866 DTE INFO DENTALEZ COM 2021 DENTALEZ Inc DENTALEZ is a registered trademark Aeras is a trademark of DENTALEZ Inc Ramvac is a registered trademark of Ramvac Dental Products Inc PN 7717 006A January 2021 Printed in USA ...

Reviews: