Denso GT10B-LU User Manual Download Page 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bar Code Handy Scanner 

GT10B-SU / GT11B-SU 
GT10B-LU 

User's Manual 

Summary of Contents for GT10B-LU

Page 1: ...Bar Code Handy Scanner GT10B SU GT11B SU GT10B LU User s Manual...

Page 2: ...application or use of any product circuit or application described herein If it is judged by DENSO WAVE INCORPORATED that malfunction of the product is due to the product having been dropped or subje...

Page 3: ...ion of Labels 26 Chapter 7 Magic Key Control 27 Chapter 8 Scanning Functions 28 8 1 Data Verification Mode 28 8 1 1 Verification setup procedure 28 8 1 2 Verification conditions 29 8 1 3 Verification...

Page 4: ...d Interface 40 11 2 USB COM Interface 40 11 3 Communication Format 41 Chapter 12 Parameters and Defaults 45 Chapter 13 Bar Coded Parameter Menu 56 13 1 Parameter Setting Procedure Using the Bar Coded...

Page 5: ...e procedures for handling connecting operating and cleaning your bar code handy scanner Before you do anything else study it carefully to make sure that you use the product both correctly and effectiv...

Page 6: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...

Page 7: ...ock If you drop the scanner so as to affect the operation or damage its housing switch off the host computer unplug the interface cable and contact your nearest dealer Failure to do so could cause fir...

Page 8: ...or electrical shock Never disassemble Never cover or wrap up the scanner in a cloth or blanket Doing so could cause the unit to heat up inside deforming its housing resulting in a fire Always use the...

Page 9: ...window will affect reading performance If you use the scanner in dusty areas therefore periodically check the clear plate and clean it if dusty To clean the plate first blow the dust away with an air...

Page 10: ...r code to read Magic key This acts as an auxiliary key for scans and data transfers Refer to Chapter 7 for details Indicator LED This turns blue after a successful read and red if there is an error Re...

Page 11: ...nterface allows you to use the scanner in applications using the conventional serial port For instructions how to set up the device driver refer to Chapter 3 Section 3 2 For the interface specificatio...

Page 12: ...ow hold the scanner body align the mark on the cable connector with that on the scanner and fully insert the interface cable connector 3 Align the two bosses on the connector cover with cutouts in the...

Page 13: ...y not be connected to some types of hubs If the operation of the hub connected scanner is unstable connect it directly to any USB port on the host computer Do not use any extension cord 3 1 Setting up...

Page 14: ...ist of all the drivers in a specific location so you can select the driver you want and click Next 5 The following screen appears Select USB Human Interface Device and click Next 6 When the following...

Page 15: ...USB Human Interface Device is added to the sub tree of Human Interface Devices as shown below the scanner is connected normally If the device is not listed or it is marked with or perform the above co...

Page 16: ...onnection process above again If marked with the device is disabled so enable it in the Property dialog If marked with a the device is working normally The scanner is designed to work with the default...

Page 17: ...scanner interface cable to the computer or USB hub The Found New Hardware hint pops up on the Windows task tray 3 Wait for a moment Windows will automatically configure the scanner Upon completion of...

Page 18: ...is impossible to install our USB COM device driver any similar USB device driver may have been already installed on your computer If it has remove the USB device driver from the device manager and in...

Page 19: ...iles 4 Remove the following files if any at the following locations C Winnt Inf Dwcom inf Dwcom pnf Dwcom9x inf Dwcom9x pnf Dwport inf Dwport pnf C Winnt System Dwport vxd C Winnt System32 drivers Dwc...

Page 20: ...d then click Next 5 Select the Specify a location check box specify the WIN9X folder in a folder where the downloaded file has been extracted and then click Next Note Do not specify any folder other t...

Page 21: ...wing that Windows is now ready to install the best driver for the DENSO WAVE USB COM Port then click Next 8 If the following screen appears click Finish When copying driver files is finished New Hardw...

Page 22: ...he scanner is connected normally If the device is not added or it is marked with or remove this driver with the uninstaller reboot your computer and perform the above connection process again Windows...

Page 23: ...der other than the WIN9X Doing so might affect the system Note The sample window below shows that the downloaded file is stored and extracted in the C DNWA USBCOM folder Specify the appropriate folder...

Page 24: ...SO WAVE USB COM Port is added to the sub tree of Ports COM LPT as shown below the scanner is connected normally If the device is not added or it is marked with or remove this driver with the uninstall...

Page 25: ...6 The Found New Hardware Wizard starts 3 Click Next to proceed 4 Select Search for a suitable driver for my device recommended then click Next 5 Select the Specify a location check box then click Next...

Page 26: ...Doing so might affect the system Note The sample window below shows that the downloaded file is stored and extracted in the C DNWA USBCOM folder Specify the appropriate folder in your computer instea...

Page 27: ...e of Ports COM LPT as shown below the scanner is connected normally If the device is not added or it is marked with or remove this driver with the uninstaller reboot your computer and perform the abov...

Page 28: ...older where the downloaded file has been extracted and then click Next Note Do not specify any folder other than the WIN2K Doing so might affect the system Note The sample window below shows that the...

Page 29: ...ses are completed 8 To make sure that the USB COM device driver has been successfully installed open the Windows Device Manager If DENSO WAVE USB COM Port is added to the sub tree of Ports COM LPT as...

Page 30: ...han one bar code within the field of view either causes the read to fail or produces multiple input Note Bar code orientation right side up or upside down does not matter as long as the margins are we...

Page 31: ...tware ScannerSetting in your computer The configuration software can operate via the USB COM interface If your scanner is set up with the USB keyboard interface you need to switch to the USB COM inter...

Page 32: ...ng which the scanner is ready to scan regardless of whether a bar code is read successfully or the trigger switch is released After a bar code is read successfully the ready to scan state further cont...

Page 33: ...tion LED and becomes ready to scan Z READOFF LOFF Standby commands Upon receipt of one of these commands the scanner turns off the illumination LED and switches to standby Each of these commands shoul...

Page 34: ...o 5 sec Failure notification Command input RxD Bar code Illumination LEDs Data output TxD Ready to scan command Standby command Failure notification Command input RxD Bar code Illumination LEDs Data o...

Page 35: ...within the designated range or move a bar code label within the same range The LED goes off when a bar code label is moved away from the range or stays within the range without move for approx 5 seco...

Page 36: ...sfer function Pressing the magic key transfers a character string max 10 bytes specified with the configuration software ScannerSetting 4 Ready standby switching function When the trigger switch is in...

Page 37: ...he verification parameters verification conditions and result output ways Use the bar coded parameter menu or the configuration software The indicator LED flashes in red indicating that no master bar...

Page 38: ...ication conditions All characters to check To check all characters as underlined at left for example set the following Starting position 1st character Number of characters All characters Max 32 bytes...

Page 39: ...ator Beeper Indicator LED OK vibrations NG vibrations If there is a match Emits a short beep Lights in blue Operates If there is a mismatch Emits a long beep Lights in red Operates 3 Scan lock The sca...

Page 40: ...istration the scanner can read only Standard 2of5 or Interleaved 2of5 symbols having either of those specified numbers of digits Example 123457 1234567895 Specifying the number of digits readable Firs...

Page 41: ...n conditions Bar code sample Bar code type Code 128 Data read 1234567890 Scanner settings Header STX Terminator ETX Prefix Suffix None Code ID mark Type 1 Transmission of number of digits 2 digits 1 E...

Page 42: ...n bar code data read starting from the specified start position the head to the 10th position to the end If the bar code data contains the specified string the scanner substitutes it with the specifie...

Page 43: ...on Search string Substitution string Output data 2nd position 456 A STX K08123A7890 ETX 5th position 890 XYZ STX K101234567XYZ ETX 9th position 890 XYZ Error 9 3 Blocksorting Data The scanner splits b...

Page 44: ...d below depending upon the AI conditions Bar code sample Bar code type EAN 128 Data read 01 94901234567894 11 030808 13 030810 17 040208 Scanner settings Header STX Terminator ETX Prefix Suffix None C...

Page 45: ...Note the following important rules for editing data with this scanner They apply to data extraction data substitution and blocksorting 1 Data editing applies to bar code data 2 Data editing applies t...

Page 46: ...gits 15 The output never contains Code 39 start stop characters regardless of their settings 16 Code 39 full ASCII conversion if enabled applies before data editing 17 Conversions skip FNC characters...

Page 47: ...ing does not match the editing conditions resulting in no transfer 2 Beeper volume You can adjust the beeper volume to three level High medium and low by using the bar coded parameter menu or the conf...

Page 48: ...ting The indicator LED flashes in red when no master bar code data has been stored in the scanner in the data verification mode You can disable the indicator LED with the bar coded parameter menu or c...

Page 49: ...pplied when the scanner sends data read to the host computer There are seven choices from 3 ms to 100 ms default 10 ms 11 2 USB COM Interface Installing our virtual COM port driver USB COM device driv...

Page 50: ...of the RTS output level change request at the host computer to the detection of the CTS input level change at the scanner may vary depending upon the processing capability and conditions of the host c...

Page 51: ...3 A F B A E0 EAN 8 B FF A A E4 UPC A with 2 digit add on A F A X1 UPC A with 5 digit add on A G A X2 UPC E with 2 digit add on C E H A X1 UPC E with 5 digit add on C E I A X2 EAN 13 with 2 digit add o...

Page 52: ...Conversion to UPC A enabled ZERO insertion format 0 Data 11 digit C D You can select whether or not to transmit the padding character 0 number system character leading 0 in 11 digit data and check dig...

Page 53: ...not to transmit start stop codes which are and enable conversion to Code 39 FULL ASCII Code 93 Code 128 EAN 128 Data When Code 128 is specified data in the following format is regarded as an EAN 128...

Page 54: ...rface 2 Communications parameters for USB keyboard interface The following settings take effect only when the USB keyboard interface is set up Items Parameters Defaults Refer to OFF Lowercase letter C...

Page 55: ...ults Refer to None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Header User defined None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl Terminator User defined Section 11 3 1 Can be changed only with th...

Page 56: ...n 11 2 1 4 Data transmission format and bar code symbologies Items Parameters Defaults Refer to Enable Prefix transmission Disable Enable Suffix transmission Disable Section 11 3 2 Enable Data editing...

Page 57: ...of UPC E Disable Enable Transmission of a check digit for UPC A Disable Enable Transmission of a check digit for UPC E Disable Enable Transmission of a check digit for EAN 13 Disable Enable Transmiss...

Page 58: ...or Interleaved 2of5 2 to 99 digits 99 digits See Note 3 Enable Transmission of a check digit for Interleaved 2of5 Disable Section 11 3 5 See Note 4 Enable Specification of the number of digits for Int...

Page 59: ...a check digit for Code 39 Disable Section 11 3 5 See Note 4 Enable Transmission of start stop codes for Code 39 Disable Enable Conversion to Full ASCII for Code 39 Disable Section 11 3 5 Code 93 Items...

Page 60: ...8 Disable Section 11 3 5 MSI Plessey Items Parameters Defaults Refer to Enable Scanning MSI Disable Minimum number of digits readable for MSI 3 digits Maximum number of digits readable for MSI 3 to 99...

Page 61: ...o sensing mode Section 6 1 1 sec 2 sec 3 sec 4 sec Scanning period in auto off mode 1 5 sec Section 6 1 High Sensitive Medium Scanner sensibility level in auto sensing mode Low Insensitive Section 6 3...

Page 62: ...Medium Beeper volume Low Section 10 1 Tone 1 2 0 kHz Tone 2 4 0 kHz Beeper frequency Tone 3 4 3 kHz Section 10 1 Before data transmission Trigger timing for the reading completion beeper and indicator...

Page 63: ...4th character 5th character 6th character Verification start position in data verification mode 7th character 1 character 2 characters 3 characters 4 characters 5 characters 6 characters 7 characters...

Page 64: ...Speed priority scanning Speed depth priority scanning Depth priority scanning Chapter 3 See Note 5 Note 5 The default is speed priority scanning for the GT10B SU GT11B SU and depth priority scanning...

Page 65: ...ar codes within three minutes Otherwise the scanner cancels newly settings and returns to the previous ones End setting Scan the End setting bar code Three beeps Scanning the All defaults bar code in...

Page 66: ...n be set by only scanning the following bar codes No Start setting or End setting bar code is required to be scanned Adjusting the beeper volume Scanning the following bar code cycles between the High...

Page 67: ...s that of the connected keyboard Caps Lock OFF default Caps Lock ON Keyboard type USB keyboard interface Select the keyboard type that is set up in the host computer U S English 101 Keyboard default G...

Page 68: ...59 Header USB keyboard interface None default STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...

Page 69: ...60 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER default Right Ctrl...

Page 70: ...transmission interval USB keyboard interface You can select the data transmission intervals at which the scanner transfers bar code data to the host computer 3 ms 6 ms 10 ms default 16 ms 30 ms 50 ms...

Page 71: ...terface Communications protocol USB COM interface Non acknowledge mode default ACK NAK mode CTS signal monitor USB COM interface Enable Disable Default Header USB COM interface None default STX Termin...

Page 72: ...le Disable default Code ID mark position Before prefix After prefix default Code ID mark Type 1 DENSO 1 default Type 2 DENSO 2 Type 3 Type 4 Type 5 AIM Transmission of the number of digits not applica...

Page 73: ...add on digits Enable 5 digit add on only Enable 2 digit add on only Disable default Transmission of the number system character of UPC A Enable default Disable Transmission of the number system charac...

Page 74: ...C E Enable Disable default Transmission of a check digit for UPC A Enable default Disable Transmission of a check digit for UPC E Enable default Disable Transmission of a check digit for EAN 13 Enable...

Page 75: ...Conversion to UPC A Enable conversion ZERO suppression format default Disable conversion ZERO insertion format Transmission of country code for EAN 13 Enable default Disable Conversion to ISBN ISSN fo...

Page 76: ...rd 2of5 by bar code scanning Enable Disable default Interleaved 2of5 Scanning Interleaved 2of5 Enable without C D default Enable with C D Disable Transmission of a check digit for Interleaved 2of5 Ena...

Page 77: ...with C D Disable Transmission of a check digit for Codabar NW 7 Enable default Disable Calculation method for a check digit of Codabar NW 7 MOD 16 default 7 check method Transmission of start stop co...

Page 78: ...e with C D Disable Transmission of a check digit for Code 39 Enable default Disable Transmission of start stop codes for Code 39 Enable Disable default Conversion to Full ASCII for Code 39 Enable Disa...

Page 79: ...de 128 Enable default Disable Scanning EAN 128 Enable default Disable Transmission of FNC1 for Code 128 and EAN 128 Transmit GS default Disable MSI Scanning MSI Enable Disable default Plessey Scanning...

Page 80: ...control Auto off mode 1 Auto off mode 2 Momentary switching mode 1 default Momentary switching mode 2 Continuous reading mode Auto sensing mode Magic key control Illumination switching function Data...

Page 81: ...eper indicator LED and vibrator Beeper Enable default Disable Trigger timing for the reading completion beeper and indicator LED Before data transmission default After data transmission Indicator LED...

Page 82: ...ication mode Report of match mismatch status Disable Disable default Enable bar code data transmission Disable Enable bar code data transmission Enable NG transmission Enable OK transmission Enable NG...

Page 83: ...ers 3 characters 4 characters 5 characters 6 characters 7 characters Not specified default Scan lock in data verification read Enable Disable default Notification of a scanning failure that occurred u...

Page 84: ...em 3 Bar code data cannot be displayed normally on the computer screen USB keyboard interface Probable cause What to do The keyboard type selected may not match one that is set up in the host computer...

Page 85: ...ion in Auto off mode 1 Typical at 5 0 VDC In operation 170 mA On standby 25 mA In suspend mode 0 5 mA Operating temperature range 0 to 50 C Operating humidity range 10 to 90 RH Without condensation or...

Page 86: ...77 Reading diagrams GT10B SU GT11B SU Speed priority scanning Depth priority scanning...

Page 87: ...78 Reading diagrams GT10B LU Speed priority scanning Depth priority scanning...

Page 88: ...0786 UPC A 4906906 4901567014010 UPC E EAN 13 49400397 0440238 10 EAN 8 UPC E with 2 digit add on 9780330290951 90000 0123457 EAN 13 with 5 digit add on Standard 2of5 0123456784 b 0B Interleaved 2of 5...

Page 89: ...80 121347 Code 128 11970 1234558 EAN 128 MSI 98765C9 Plessey...

Page 90: ...Bar Code Handy Scanner GT10B SU GT11B SU GT10B LU User s Manual First Edition February 2004 Fourth Edition August 2005 DENSO WAVE INCORPORATED...

Page 91: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com...