Bar Code Handy Scanner
GT10B-SB
GT10B-LB
User's Manual
Page 1: ...Bar Code Handy Scanner GT10B SB GT10B LB User s Manual...
Page 2: ...re not supplied from DENSO WAVE ii the use of DENSO WAVE s products in a manner for which the same were not intended nor designed or iii any modification of DENSO WAVE s products by other s than DENSO...
Page 3: ...nergy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a parti...
Page 4: ...t name Bluetooth Board Product model Number DWBT002 Essential Requirement and Harmonized Standards applied Health and safety requirements pursuant to 3 1 a EN60950 Applied Standard s or other means of...
Page 5: ...tion of Labels 15 5 4 Reading with Scanner Mounted on Charger 16 Chapter 6 Magic Key Control 17 Chapter 7 Scanning Functions 19 7 1 Data Verification Mode 19 7 1 1 Verification setup procedure 19 7 1...
Page 6: ...software control 61 7 Speed depth priority scanning 62 8 Switching to sleep mode for power saving 62 9 For Bluetooth adapter Bluetooth communications parameters 63 10 For Bluetooth adapter Interfaces...
Page 7: ...ons parameters 93 USB keyboard interface communications parameters 94 USB COM interface communications parameters 96 RS 232C interface communications parameters 97 PS 2 keyboard interface communicatio...
Page 8: ...e procedures for handling connecting operating and cleaning your bar code handy scanner Before you do anything else study it carefully to make sure that you use the product both correctly and effectiv...
Page 9: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...
Page 10: ...cartridge into a microwave oven or high pressure container Doing so could cause the batteries to break generate heat rupture or burn Avoid dropping the battery cartridge or letting it undergo any sho...
Page 11: ...s well as damage to the scanner Never put the battery cartridge into a microwave oven or high pressure container If smoke abnormal odors or noises come from the scanner immediately remove the battery...
Page 12: ...place heavy material on the cable or allow the cable to get pressed under heavy material Doing so could break the cable resulting in a fire Keep the AC adapter away from water Failure to do so could...
Page 13: ...nner or AC adapter in a cloth or blanket Doing so could cause the scanner or AC adapter to heat up inside deforming its housing resulting in a fire Always use the scanner or AC adapter in a well venti...
Page 14: ...rtridge When taking care of the AC adapter unplug it from the electrical outlet for safety Failure to do so could result in an electrical shock Do not drop the scanner or AC adapter The housing may be...
Page 15: ...Components required for individual interfaces For RS 232C interface 5 RS 232C interface cable CBBA RS2000 9 6 AC adapter AD2 2005 3000 USA AD2 3005 3000 EU For Bluetooth adapter For RS 232C interface...
Page 16: ...tworking The following environments can sometimes block wireless networking Metal objects or particles in the vicinity Metal walls around the area Excessive vibration The communications range of 10 m...
Page 17: ...or it and remove it as the usage environment warrants To clean the plate first blow the dust away with an airbrush Then gently wipe the plate with a cotton swab or the similar soft one If sand or hard...
Page 18: ...h Press this to read a bar code or initiate a Bluetooth wireless link The following trigger switch operating modes are available Auto off mode 1 Auto off mode 2 Momentary switching mode 1 Momentary sw...
Page 19: ...operation Scanning it enables the Bluetooth interface Start operation Note Always disable this scanner s Bluetooth interface in hospitals aircraft and other environments where the Bluetooth radio wav...
Page 20: ...dicator LED to turn green for 0 5 second Using some other Bluetooth device To configure the scanner as a master and some other Bluetooth equipment as a slave follow the sample procedures given below a...
Page 21: ...t Label button Pressing the Preview button displays the Bluetooth address bar code created The displayed bar code can be read with the scanner 6 On the window shown below press the Print button to pri...
Page 22: ...ommunication procedures 1 If the scanner is currently a master read the following bar code to switch it to slave operation Configure as slave 2 Wait for the scanner to beep three times press the scann...
Page 23: ...wireless link has been broken by any of the following events pressing the trigger switch reestablishes the Bluetooth wireless link The scanner as a slave waits for a connection request from the maste...
Page 24: ...scanner has scanned the End operation bar code When the trigger switch is pressed and released Indicator LED Beeper Scanner Status Blue blinking rapidly The scanner as a master is searching for a con...
Page 25: ...oximately 17 cm 6 69 for a scan distance of 18 cm 7 09 Note Having more than one bar code within the field of view either causes the read to fail or produces multiple input Note Bar code orientation r...
Page 26: ...row data read and then sends the data to the host To inform the user that the 1st or 2nd row data has accumulated in the scanner the scanner emits a one shot beep by default Upon completion of a succe...
Page 27: ...or disabling switching to sleep mode shortens the operation time of the battery cartridge Scanning with Bluetooth wireless link broken The scanner can read bar codes even with the Bluetooth wireless...
Page 28: ...ded that the scanner be configured as a master This software also offers batch process bar code printouts for read by scanners in the field Registered users can download the configuration software Sca...
Page 29: ...of whether a bar code is read successfully or the trigger switch is released After a bar code is read successfully the ready to scan state further continues for approx 5 seconds If the scanner is lef...
Page 30: ...becomes ready to scan Z READOFF LOFF Standby commands Upon receipt of one of these commands the scanner turns off the illumination LED and switches to standby Each of these commands should be enclose...
Page 31: ...to 5 sec Failure notification Standby command Ready to scan command Bar code data Ready to scan command Failure notification Command input RxD Bar code Illumination LED Data output TxD Command input...
Page 32: ...her sensitivity level if the illumination LED will not come on when a bar code is brought into the range for example Note Even if you do not bring a bar code label within the scan range the illuminati...
Page 33: ...tandby intervals between reads Configuring for continuous reading or auto sensing mode however disables recharging Trigger switch operating mode Scanner state Auto off mode 1 Auto off mode 2 Momentary...
Page 34: ...ng cases that follow bar code reading When the scanner has read the Start operation or End operation bar code When you have customized the scanner by modifying the parameters with the configuration so...
Page 35: ...inuous reading mode Auto sensing mode Illumination switching function Data retransfer function Specific character transfer function Ready standby switching function Auto sensing mode switching functio...
Page 36: ...tion parameters can be specified using the bar coded parameter menu or configuration software ScannerSetting After specifying them scan a master bar code and the scanner becomes capable of data verifi...
Page 37: ...option readies the scanner for registering new master data after bar code reading no matter what the verification result is Note Any of the following events clears the master data stored in the scann...
Page 38: ...12345601 Verification conditions All characters to check To check all characters as underlined at left for example set the following Starting position 1st character Number of characters All character...
Page 39: ...coded parameter menu or configuration software ScannerSetting Once the scanner is locked it switches to standby regardless of the current trigger switch control selected The scanner remains on standby...
Page 40: ...ata 7 1 5 Breaking the Bluetooth wireless link with no master data registered To break the Bluetooth wireless link with no master data registered follow the procedure given below Break Bluetooth wirel...
Page 41: ...can 6 digit Interleaved 2of5 symbol Just the bar code type and the number of digits will be stored in the scanner The code data will be sent Second scan 10 digit Interleaved 2of5 symbol Just the bar c...
Page 42: ...n conditions Bar code sample Bar code type Code 128 Data read 1234567890 Scanner settings Header STX Terminator ETX Prefix Suffix None Code ID mark Type 1 Transmission of number of digits 2 digits 1 E...
Page 43: ...ode data read starting from the specified start position the head to the 10th position to the end If the bar code data contains the specified string the scanner substitutes it with the specified subst...
Page 44: ...position Search string Substitution string Output data 2nd digit 456 A STX K08123A7890 ETX 5th digit 890 XYZ STX K101234567XYZ ETX 9th digit 890 XYZ Error 8 3 Blocksorting Data The scanner splits bar...
Page 45: ...code and scanner settings output data as listed below depending upon the AI conditions Bar code sample Bar code type EAN 128 Data read 01 94901234567894 11 030808 13 030810 17 040208 Scanner settings...
Page 46: ...iting data with this scanner They apply to data extraction data substitution and blocksorting 1 Data editing applies to bar code data 2 A search string should consist of ASCII characters 00h to 7Fh an...
Page 47: ...ata according to the definition of the table below The format in the AI table is coded as listed below a Alphabetic character a3 Three digits alphabetic characters a 3 Up to three digits alphabetic ch...
Page 48: ...h or 1st Dimension Yards 324n n4 n6 Width Diameter or 2nd Dimension Inches 325n n4 n6 Width Diameter or 2nd Dimension Feet 326n n4 n6 Width Diameter or 2nd Dimension Yards 327n n4 n6 Depth Thickness H...
Page 49: ...ume Gallons 364n n4 n6 Volume Cubic Inches 365n n4 n6 Volume Cubic Feet 366n n4 n6 Volume Cubic Yards 367n n4 n6 Gross Volume Cubic Inches 368n n4 n6 Gross Volume Cubic Feet 369n n4 n6 Gross Volume Cu...
Page 50: ...l Number of Processor with Three Digit ISO Country Code 2nd to 9th Processing Places 8001 n4 n14 Roll Products Width Length Core Diameter Direction and Splices 8002 n4 an 20 Cellular Mobile Telephone...
Page 51: ...mpany Internal Information To indicate only year and month DD must be FILLED with 00 n indicates the length of data n indicates the decimal point position n indicates the number of digits after decima...
Page 52: ...versa the scanner has read the START or END bar code out of batch process bar code symbols generated with the configuration software the configuration software starts up or accepts new setting a Blue...
Page 53: ...rameter settings When the Bluetooth wireless link is established or broken When transfer of Bluetooth adapter parameter settings is normally ended When the charge of the battery cartridge has lowered...
Page 54: ...s read a bar code except a master bar code for data verification successfully with the auto sensing mode switching function being enabled or the Bluetooth wireless link is ready for use Lights in red...
Page 55: ...s displayed 9 3 Vibrator The bar coded parameter menu and configuration software ScannerSetting provide three configuration choices indicating successful scanning OK indicating an error NG and disable...
Page 56: ...Bluetooth device or other equipment For further details see Section 10 3 2 Timeout period for slave to wait for a connection request The scanner as a slave waits for a connection request from the mas...
Page 57: ...or 1 Header Terminator The following choices are available Header None default or STX Terminator CR default LF CR LF ETX or none Note Selecting none for a terminator automatically uses a CR terminator...
Page 58: ...with 2 digit add on C E H A X1 X3 UPC E with 5 digit add on C E I A X2 X3 EAN 13 with 2 digit add on A F L A E1 E3 EAN 13 with 5 digit add on A F M A E2 E3 EAN 8 with 2 digit add on B FF J A E5 EAN 8...
Page 59: ...is enabled ZERO insertion format 0 Data 11 digit C D You can select whether or not to transmit the padding character 0 number system character leading 0 in 11 digit data and a check digit to the host...
Page 60: ...Conversion from Code 39 to Code 32 format is enabled Code 39 data is 6 digits long Code 39 consists of any of 0 to 9 and alphabets except A E I and O and The conversion result is within the range from...
Page 61: ...14 digit PI 0 Data 11 digit C D ADD ON data 2 or 5 digit UPC A with add on 16 digit 01 PI 0 Data 11 digit C D ADD ON data 2 or 5 digit 14 digit PI 0 Data 11 digit C D ADD ON data 2 or 5 digit UPC E wi...
Page 62: ...NAK responses even when the data has been correctly transmitted It is therefore important to use the scanner in an environment supporting stable wireless communications Data transmission format Heade...
Page 63: ...Bluetooth adapter Scanner settings Data packaging mode to host c Transfer data packets d Send ACK for a successful transfer NAK for an unsuccessful one e Return ACK and transfer the data packets to th...
Page 64: ...ces overflow XOR the current CRC value with 0001h 5 Repeat steps 3 and 4 a total of 8 times 6 Retrieve the second data byte 13h 7 Repeat steps 3 and 4 a total of 8 times 8 Repeat this calculation thro...
Page 65: ...40 C Ambient temperature of 10 to 30 C recommended Humidity of 20 to 80 No dust or excessive vibration No splashing of water or other liquids Do not leave the charger in direct sunlight in an automobi...
Page 66: ...echarge followed by one hour use the operation period will become abnormally shortened before the service life is really expired just as the battery memorizes the usage conditions It is called Memory...
Page 67: ...ke the battery cartridge out of the scanner due to any scanner trouble 1 Remove the screw that secures the battery cover 2 Open the battery cover gently that is connected with the cable 3 Pull up the...
Page 68: ...ce around the battery cartridge to prevent them from getting pinched between the battery cover and the case and then close the battery cover and secure it with the screw Note After loading a new batte...
Page 69: ...d out wheeled bin is applicable for EU member status only Used battery cartridges must not be disposed of as combustibles Contact your nearest rechargeable battery recycling centre or local sales offi...
Page 70: ...ata packaging mode to BA10 RKU Section 10 1 1 None Header STX ETX CR LF CR LF Terminator None Section 10 2 1 1 ACK NAK response time 1 to 25 seconds 0 1 to 9 9 seconds on models that do not support da...
Page 71: ...nable in 4 digits Enable in 2 digits Transmission of the number of digits not applicable to UPC EAN codes Disable Section 10 2 1 4 Enable GTIN format conversion Disable Section 10 2 2 16 digit GTIN fo...
Page 72: ...n of a check digit for UPC A Disable Enable Transmission of a check digit for UPC E Disable Enable Transmission of a check digit for EAN 13 Disable Enable Transmission of a check digit for EAN 8 Disab...
Page 73: ...ved 2of5 2 to 99 digits 99 digits See Note 2 Enable Transmission of a check digit for Interleaved 2of5 Disable Section 10 2 1 5 See Note 3 Enable Specification of the number of digits for Interleaved...
Page 74: ...able for Code 39 1 to 99 digits excluding start stop codes 99 digits See Note 2 Enable Transmission of a check digit for Code 39 Disable Section 10 2 1 5 See Note 3 Enable Transmission of start stop c...
Page 75: ...MSI Disable Minimum number of digits readable for MSI 3 digits Maximum number of digits readable for MSI 3 to 99 digits including 2 digit C D 99 digits See Note 2 Enable Scanning Plessey Disable Mini...
Page 76: ...4 sec Scanning period in auto off mode 1 5 sec Section 5 1 High Sensitive Medium Scanner sensibility level in auto sensing mode Low Insensitive Section 5 3 Illumination switching function Chapter 6 D...
Page 77: ...ransmission Enable Beeper when reading RSS 14 Stacked and RSS 14 Stacked Omnidirectional Disable One shot beep Beeping pattern when reading RSS 14 Stacked and RSS 14 Stacked Omnidirectional Intermitte...
Page 78: ...2nd character 3rd character 4th character 5th character 6th character Verification start position in data verification mode 7th character 1 character 2 characters 3 characters 4 characters 5 characte...
Page 79: ...efault is speed priority scanning for the GT10B SB and depth priority scanning for the GT10B LB 8 Switching to sleep mode for power saving Items Parameters Defaults Refer to Immediately 5 seconds 15 s...
Page 80: ...For Bluetooth adapter USB keyboard interface communications parameters The following settings take effect only when the USB keyboard interface is set up Items Parameters Defaults Refer to Auto settin...
Page 81: ...ta transmission format Enabling this function substitutes E7h to FDh data with the special keys as listed below and transmits the substituted data to the host The Left SHIFT Left CTRL and Left ALT are...
Page 82: ...monitor Disable 13 For Bluetooth adapter RS 232C interface communications parameters The following settings take effect when the RS 232C interface is set up Items Parameters Defaults Refer to 1200 bp...
Page 83: ...rd OFF See Note 8 U S English 101 keyboard Germany 102 keyboard French 102 keyboard U K English 102 keyboard Italian 102 keyboard Swedish 102 keyboard Japanese 106 keyboard IBM 5576 001 Keyboard type...
Page 84: ...s function substitutes E7h to FDh data with the special keys as listed below and transmits the substituted data to the host The Left SHIFT Left CTRL and Left ALT are transmitted as a simultaneous depr...
Page 85: ...e Substitution of header Disable Search string for header Single ASCII character 00h to 7Fh Substitution string for header Max 4 ASCII characters 00h to 7Fh and E7h to FDh Enable Substitution of termi...
Page 86: ...ng bar codes Scan desired parameter setting bar codes Note When using the bar coded parameter menu scan bar codes within three minutes Otherwise the scanner cancels new settings and returns to the pre...
Page 87: ...the Scan w Bluetooth link broken bar code allows the scanner to scan bar codes with the Bluetooth wireless link being broken With this setting selected data transfer with the host computer is impossib...
Page 88: ...cedure and reverting to defaults To set parameters given on the following pages it is necessary to scan the Start setting bar code To complete the setting procedure scan the End setting bar code Start...
Page 89: ...ace communications parameters Communications protocol Non acknowledge mode default ACK NAK mode Data packaging mode to host Data packaging mode to BA10 RKU Header None default STX Terminator ETX CR de...
Page 90: ...3 Timeout period for slave to wait for a connection request 2 minutes default 4 minutes 10 minutes 30 minutes Clearing the transfer buffer when the Bluetooth wireless link breaks Enable Disable defaul...
Page 91: ...le default Code ID mark position Before prefix After prefix default Types of code ID mark Type 1 DENSO 1 default Type 2 DENSO 2 Type 3 Type 4 Type 5 AIM Type 6 AIM Type 2 Transmission of the number of...
Page 92: ...add on digits Enable 5 digit add on only Enable 2 digit add on only Disable default Transmission of the number system character of UPC A Enable default Disable Transmission of the number system charac...
Page 93: ...C E Enable Disable default Transmission of a check digit for UPC A Enable default Disable Transmission of a check digit for UPC E Enable default Disable Transmission of a check digit for EAN 13 Enable...
Page 94: ...ission format of UPC E Conversion to UPC A Enable conversion Disable conversion default Transmission of country code for EAN 13 Enable default Disable Conversion to ISBN ISSN format for EAN 13 Enable...
Page 95: ...rd 2of5 by bar code scanning Enable Disable default Interleaved 2of5 Scanning Interleaved 2of5 Enable without C D default Enable with C D Disable Transmission of a check digit for Interleaved 2of5 Ena...
Page 96: ...lt Enable with C D Disable Transmission of a check digit for Codabar NW 7 Enable default Disable Check digit method for Codabar NW 7 MOD 16 default 7 check method Transmission of start stop codes for...
Page 97: ...Code 32 Conversion from Code 39 to Code 32 format Enable Disable default Transmission of leading A in Code 32 data Enable Disable default Checking of a check digit in Code 32 data Enable Disable defau...
Page 98: ...e with C D Disable Transmission of a check digit for Code 39 Enable default Disable Transmission of start stop codes for Code 39 Enable Disable default Conversion to Full ASCII for Code 39 Enable Disa...
Page 99: ...ble default Disable Scanning EAN 128 Enable default Disable Transmission of FNC1 for Code 128 and EAN 128 Transmit after conversion to GS default Disable MSI Scanning MSI Enable Disable default Plesse...
Page 100: ...Disable default GTIN GTIN format conversion Enable Disable default Conversion type from EAN UPC Interleaved 2of5 14 digit to GTIN format 16 digit GTIN format default 14 digit GTIN format Disable conv...
Page 101: ...e 1 default Momentary switching mode 2 Continuous reading mode Auto sensing mode Magic key control Illumination switching function Data retransfer function Specific character transfer function Ready s...
Page 102: ...Trigger timing for the reading completion beeper and indicator LED Before data transmission default After data transmission Beeper when reading RSS 14 Stacked and RSS 14 Stacked Omnidirectional Enabl...
Page 103: ...NG vibrations Disable Data verification mode Data verification mode Regular read mode default Data verification mode Data verification type 2 point verification n point verification default Verificati...
Page 104: ...n default Enable bar code data transmission Disable transmission Enable bar code data transmission Enable NG transmission Enable OK transmission Enable NG transmission Verification start position in d...
Page 105: ...aracters 3 characters 4 characters 5 characters 6 characters 7 characters Not specified default Scan lock in data verification read Enable Disable default Notification of a scanning failure under soft...
Page 106: ...89 Reading with scanner mounted on charger Enable Disable default...
Page 107: ...provided on the bottom of the Bluetooth adapter for at least 0 5 second with a pin or the like to switch to the setup mode Note Leaving the Bluetooth adapter for 3 minutes or more after depression of...
Page 108: ...nd normally the scanner s indicator LED turns red with three beeps Both the scanner and Bluetooth adapter automatically reset themselves regardless of whether the parameter transfer ends normally Blue...
Page 109: ...luetooth Adapters Starting and ending the setting procedure and restoring to defaults Start setting End setting All defaults Setting the interface USB keyboard interface default USB COM interface RS 2...
Page 110: ...face communications parameters Clearing the transfer buffer when the Bluetooth wireless link breaks Enable Disable default Connection target GT10 series default Others Reception of split packets Enabl...
Page 111: ...l setting Caps Lock of host s keyboard USB keyboard interface ON OFF default Keyboard type USB keyboard interface Select the connected keyboard type U S English 101 keyboard default Germany 102 keyboa...
Page 112: ...ission intervals that apply when the Bluetooth adapter transfers data read by the scanner to the host computer 3 ms default 6 ms 10 ms 16 ms 30 ms 50 ms 100 ms Numeric key type USB keyboard interface...
Page 113: ...96 USB COM interface communications parameters Monitoring CTS USB COM interface Enable default Disable...
Page 114: ...arameters Transmission speed RS 232C interface 1200 bps 2400 bps 4800 bps 9600 bps default 14400 bps 19200 bps 38400 bps 57600 bps 115200 bps Data bit RS 232C interface 7 bits 8 bits default Parity RS...
Page 115: ...98 Stop bit RS 232C interface 1 bit default 2 bits Monitoring CTS RS 232C interface Enable default Disable...
Page 116: ...Caps Lock state that matches the host s keyboard state OFF default ON Num Lock mode PS 2 keyboard interface Select the Num Lock state that matches the host s keyboard state ON default OFF Keyboard typ...
Page 117: ...too short interval may cause the computer to fail to display bar code data correctly e g character missing If it happens set a longer interval 1 ms default 5 ms 10 ms 15 ms 30 ms 50 ms 100 ms Numeric...
Page 118: ...g efficiency Probable cause What to do A target bar code is not within the scan range of the reading window Bring a bar code within the scan range See Chapter 3 The bar code may be smeared Either wipe...
Page 119: ...the charger Remove the scanner from the charger for reads The Reading with scanner mounted on charger has not been enabled Enable reading on the charger Problem 7 Using data packaging packetizing prod...
Page 120: ...Power source Operating voltage 2 4 VDC Operating time per charge reference value 35 hours at Ta 25 C 2 Operating temperature range 0 to 50 C Operating humidity range 10 to 90 RH 3 Storage temperature...
Page 121: ...ls 0 25 13 0 mils 0 33 19 7 mils 0 5 0 53 13 5 3 94 100 1 97 50 0 5 91 150 0 53 13 5 4 9 mils 0 125 Depth priority scanning 3 94 100 5 91 150 Scan range incl right and left margins 1 97 50 0 0 Scan di...
Page 122: ...odule size 0 0 39 10 0 39 10 7 5 mils 0 19 9 8 mils 0 25 13 0 mils 0 33 19 7 mils 0 5 39 4 mils 1 0 Depth priority scanning 7 87 200 11 81 300 Scan range incl right and left margins 3 94 100 0 15 75 4...
Page 123: ...20786 UPC A 4906906 4901567014010 UPC E EAN 13 49400397 0440238 10 EAN 8 UPC E with 2 digit add on 9780330290951 90000 0123457 EAN 13 with 5 digit add on Standard 2of5 0123456784 b 0B Interleaved 2of5...
Page 124: ...107 121347 Code 128 11970 1234558 EAN 128 MSI 98765C9 01 12345678901231 Plessey RSS 14 01 12345678901231 01 12345678901231 RSS 14 Stacked RSS Limited...
Page 125: ...used to authenticate two Bluetooth devices in pairing Once authentication is performed no Bluetooth passkey input is required for the next authentication Local Name Bluetooth Device Name This is a us...
Page 126: ...ng from the scanner The following is the procedure for initiating pairing with the target Bluetooth device from the scanner Scanner Store connection data for target Bluetooth device Use the scanner co...
Page 127: ...n 2 minutes 30 seconds Scanner s indicator LED Flashes green flashing pattern similar to connection as slave Target Bluetooth device Start pairing sequence Select the scanner for pairing from the list...
Page 128: ...ttp www qbdirect net Before downloading you are requested to register as a member free of charge Changing Bluetooth adapter s interface to USB keyboard interface The following is the procedure for cha...
Page 129: ...uctions install the USB COM port driver New Hardware Found wizard Windows Me or Add New Hardware Wizard Windows 98 98SE For further details on installing the USB COM port driver refer to the Bluetooth...
Page 130: ...the target Bluetooth adapter Reading in the Bluetooth adapter s bar code configures the scanner as a master and initiates connection to the Bluetooth adapter 2 Successful connection sounds the scanne...
Page 131: ...manuals are available as free downloads from our website QBdirect at http www qbdirect net Before downloading you are requested to register as a member free of charge Changing Bluetooth adapter s inte...
Page 132: ...ructions install the USB COM port driver New Hardware Found wizard Windows Me or Add New Hardware Wizard Windows 98 98SE For further details on installing the USB COM port driver refer to the Bluetoot...
Page 133: ...th adapter 1 Use the scanner to read the bar code printed on the back of the target Bluetooth adapter Reading in the Bluetooth adapter s bar code configures the scanner as a master and initiates conne...
Page 134: ...s Communications HyperTerminal for Windows XP 2 Create new connection On the Connection Settings screen create a new connection Name Enter an easy to understand name Our example uses GT10 Icon Select...
Page 135: ...te if the data displays normally As an alternative to HyperTerminal the Denso keyboard interface QR_kbif software allows the display of data from the scanner on the computer screen for any program acc...
Page 136: ...p www qbdirect net Before downloading you are requested to register as a member free of charge Changing Bluetooth adapter s interface to RS 232C interface The default interface of the Bluetooth adapte...
Page 137: ...the configuration software BASetting on the computer Press the OK button when the following screen appears 5 When the following screen appears specify the port number connected to the Bluetooth adapte...
Page 138: ...th status display LED on the Bluetooth adapter also lights Displaying data from scanner on computer The following is the procedure for displaying data from the RS 232C interface on the computer screen...
Page 139: ...es then press the OK button This completes HyperTerminal setup 5 Read a bar code with the scanner Setup is complete if the data displays normally As an alternative to HyperTerminal the Denso keyboard...
Page 140: ...h adapters AC adapter Software Configuration software BASetting for Bluetooth adapters For using a USB port USB COM port driver Manuals Bar Code Handy Scanner User s Manual this book Bluetooth Adapter...
Page 141: ...terface and then specify the keyboard type and others An incorrect setting garbles some characters 4 On the file menu choose Apply new settings to switch the Bluetooth adapter s interface to the PS 2...
Page 142: ...initiates connection to the Bluetooth adapter 2 Successful connection sounds the scanner beeper twice and switches the scanner s indicator LED to green for 0 5 second The blue Bluetooth status display...
Page 143: ...Bar Code Handy Scanner GT10B SB GT10B LB User s Manual First Edition October 2004 Fourth Edition September 2008 DENSO WAVE INCORPORATED...
Page 144: ...DENSO WAVE INCORPORATED 4 2 12 Toranomon Minato ku Tokyo Japan 105 0001 http www denso wave com...