Denso AT20B-SM User Manual Download Page 1

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Barcode Handy Scanner 

AT20B-SM 
AT21B-SM 

User’s Manual 

Summary of Contents for AT20B-SM

Page 1: ...Barcode Handy Scanner AT20B SM AT21B SM User s Manual...

Page 2: ...lisher All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders Microsoft Windows is a trademark of Microsoft Corporation Other produ...

Page 3: ...Trigger Switch Control 11 6 2 Software Control 12 6 3 Reading by Automatic detection of labels 12 Chapter 7 Reading Functions 14 7 1 Data Verification Mode 14 7 1 1 Data verification read procedure 14...

Page 4: ...ded Parameter Menu 68 11 1 Parameter Setting Procedure Using the Bar coded Parameter Menu 68 11 2 Bar coded Parameter Menu 69 Chapter 12 Troubleshooting 89 Appendix 1 Specifications 91 Appendix 2 Cont...

Page 5: ...product having been dropped or subjected to impact repairs will be made at a reasonable charge even within the warranty period Intellectual Property Precaution DENSO WAVE INCORPORATED DENSO WAVE takes...

Page 6: ...for new products Free web information service QBdirect QBdirect Service Contents Information search service FAQ Offers detailed information on each product Download service Offers downloads of repair...

Page 7: ...se conditions that could cause serious bodily injury or death if the instructions are not followed correctly Alerts you to those conditions that could cause minor bodily injury or substantial property...

Page 8: ...t pull or heat the power cable of the AC adapter Do not place heavy material on the cable or allow the cable to get pressed under heavy material Doing so could break the cable resulting in a fire Do n...

Page 9: ...ble of the AC adapter away from any heating equipment Failure to do so could melt the sheathing resulting in a fire or electrical shock Do not scratch or modify the scanner or its interface cable Do n...

Page 10: ...fire or electrical shock During electrical storm activity always unplug the AC adapter from the wall socket Exposure to power surges could result in a damaged scanner or fire When taking care of the...

Page 11: ...plate with a cotton swab or the similar soft one gently If sand or hard particles have accumulated never rub the plate doing so will scratch or damage it Blow the particles away with an airbrush or a...

Page 12: ...hen reading is complete Beep hole The beeper sounds when the scanner has read a barcode successfully Case AT20B Light gray AT21B Black Bottom Case Trigger switch Press this switch to start Barcode rea...

Page 13: ...actory default Host computer PC AT or AT AT compatible PC equipped with a USB port Operating System OS Windows XP x32 Edition Windows Vista x32 Edition Windows 7 x32 Edition and x64 Edition USB driver...

Page 14: ...with that on the scanner and fully insert the interface cable connector 3 Align the mark on the scanner with that on the connector cover and fully insert the connector cover to the scanner until the g...

Page 15: ...ible Doing so may result in weak contact Note Be sure to use the adapter exclusively designed for the scanner 2 Host computer powered type Connect the RS 232C interface cable to the host computer Secu...

Page 16: ...may take several to 10 seconds to add or delete the USB device Hot plugging unplugging is allowed for USB devices However do not plug or unplug the USB connector when The computer is on standby in sus...

Page 17: ...llation of drivers containing no signature with the driver s signature option or local policy s security option The driver allows hot plugging or unplugging of a USB device even during communication w...

Page 18: ...ver This section describes the procedure on each of Windows XP and Windows Vista On Windows 7 also follow the wizard Windows 7 Windows Vista 1 Switch the computer on to run Windows 7 or Windows Vista...

Page 19: ...scanner Upon completion of the configuration the screen shown at left automatically disappears 4 To check whether the USB device is working normally open Windows Device Manager If USB Human Interface...

Page 20: ...t as possible when it is distorted The scanner may not read labels under direct sunshine or in extremely bright places The scanner can read codes bi directionally Take out the labels when it covered w...

Page 21: ...n software is available via the RS 232C interface or USB COM interface it is not via the USB keyboard interface The configuration software also offers batch process barcode symbols for read by scanner...

Page 22: ...2 Momentary switching mode The scanner is brought to the Active state only when the trigger switch is pressed and returns to the Ready state when the trigger switch is released 3 Momentary switching m...

Page 23: ...tion LEDs and starts the scanner reading the barcode No trigger switch operation is required Use this mode when the scanner is stationary to a stand and a barcode label is moved The illumination LEDs...

Page 24: ...in the scan range the illumination LEDs may come on when the ambient level of light changes or any shadows move within the scan range Note To enable the scanner to work properly in auto sensing mode a...

Page 25: ...canner Setting Up to 99 digits can be registered The registered master data will be preserved even if the scanner is turned off To clear it first clear the registered master data stored in the host co...

Page 26: ...an error The scanner becomes ready to register master data again Verification retry after mismatch in 2 point verification The 2 point verification read provides the Verification retry after mismatch...

Page 27: ...ied range Examples Master data registered Verification start position No of characters to be verified Data string read Verification object Result 345 3 3 00345 Match 345 3 3 00345678 Match 345 3 3 003...

Page 28: ...transmission 2 Beeper and indicator LED You can check whether the verification result is a match or mismatch with the beeper and indicator LED When the beeper and indicator LED are enabled they act as...

Page 29: ...7 2 1 1 Extracting a data string The scanner extracts a data string specified by the Extraction start position and Extraction end position from a code specified by the Code type and then outputs it i...

Page 30: ...ut data Head position 3rd position STX K03123 ETX Tail position 3rd position STX K03345 ETX 1st position Tail position STX K0512345 ETX 1st position By 3 positions STX K03123 ETX 2nd position 4th posi...

Page 31: ...action conditions Setting data Any code UPC A EAN 13 UPC E EAN 8 CODE128 GS1 128 EAN 128 CODABAR NW 7 CODE39 Interleaved 2 of 5 ITF Standard 2 of 5 STF CODE32 CODE93 MSI Plessey Code type GS1 DataBar...

Page 32: ...ETX 1 23 456 7890 2 and 5 STX ETX STX 7890 ETX 1 23 456 7890 5 Error 1 23 456 7890 4 and 5 Error Code type CODE128 Transmit data regardless of the results Prohibit 1234567890 1 and 2 Error 1 23 456 7...

Page 33: ...f digits is the count of each element string edited Example Data read 01 94901234567894 11 030808 13 030810 Header STX Terminator ETX Scanner ID Disable Code ID mark Disable Transmission of the number...

Page 34: ...4 030808 040208 ETX 17 11 STX 040208 030808 ETX 17 17 STX 040208 040305 ETX 12 01 12 Transmit data regardless of the results Permit 01 01 Comma STX 019490123456789411030808130308101 704020817040305 ET...

Page 35: ...BCC Disable Extraction conditions Data read Output data 0194901234567894110308081303 081017040208 STX 01 94901234567894 11 030808 13 030810 17 040208 ETX Transmit data regardless of the results Prohi...

Page 36: ...Expiration Date YYMMDD 20 n2 n2 Product Variant 21 n2 an 20 Serial Number 22 n2 an 29 HIBCC Health Industry Business Communication Council Quantity Date Batch and Link 23n n3 n 19 Batch or Lot Number...

Page 37: ...s Logistics 333n n4 n6 Area Square Meters Symbology 334n n4 n6 Gross Volume Liters 335n n4 n6 Gross Volume Cubic Meters 336n n4 n6 Kilograms per Square Meter pressure 337n n4 n6 Gross Weight Pounds 34...

Page 38: ...n15 Amount Payable and ISO Currency Code 392n n4 n15 Amount Payable for a Variable Measure Trade Item Single Monetary Area 393n n4 n3 n15 Amount Payable for a Variable Measure Trade Item and ISO Curre...

Page 39: ...or with Three Digit ISO Country Code 2nd to 9th Processing Places 8001 n4 n14 Roll Products Width Length Core Diameter Direction and Splices 8002 n4 an 20 Cellular Mobile Telephone Identifier 8003 4 n...

Page 40: ...DD must be filled with 00 n indicates the length of data n indicates the decimal point position a a3 a 3 Alphabetic characters 3 alphabetic characters fixed length Up to 3 alphabetic characters n n3 n...

Page 41: ...version conditions Setting data Any code UPC A EAN 13 UPC E EAN 8 CODE128 GS1 128 EAN 128 CODABAR NW 7 CODE39 Interleaved 2 of 5 ITF Standard 2 of 5 STF CODE32 CODE93 MSI Plessey Code type GS1 DataBar...

Page 42: ...n an error Block sorting conditions Block sorting conditions Setting data Any code UPC A EAN 13 UPC E EAN 8 CODE128 GS1 128 EAN 128 CODABAR NW 7 CODE39 Interleaved 2 of 5 ITF Standard 2 of 5 STF CODE3...

Page 43: ...when the parameter values are saved by a PW command refer to Appendix 2 and when the beeper is enabled at power ON 2 Adjusting the beeper volume You can adjust the beeper volume to three levels high m...

Page 44: ...ter refer to Appendix 2 When the configuration software Scanner Setting starts up or any setting is newly established When the scanner reads a batch process Barcode symbol When the parameter values ar...

Page 45: ...guration software 1 short beep Note 1 Lights in blue Power activation Note 3 4 short beeps Note1 The configuration software provides three choices for the beeping time of a short beep 60 80 and120 ms...

Page 46: ...35 Status Beeping Indication LED No master data has been registered in the n point verification scan mode Lights in red Repeating...

Page 47: ...ware Scanner Setting provides CTS timeout and ACK NAK response settings each from 100 ms to 9 9 s in 100 ms increments 2 RTS signal control protocol You can select either the scanner ready mode or the...

Page 48: ...to register visit the following URL http www qbdirect net Notes for use If you connect the scanner to your computer first time or have changed the COM port for the scanner or hub then confirm the COM...

Page 49: ...ements and two CTS signal control choices controlled and not controlled ACK NAK mode If the CTS signal is at high level Enable transmission the scanner transmits barcode data read After that the scann...

Page 50: ...sage Tables Version 1 11 keyboard 1 CAPS Lock state Select the CAPS Lock ON or OFF to match the state of the connected keyboard Default CAPS Lock OFF 2 Keyboard type Select the type of the connected k...

Page 51: ...C ENTER default or others For details refer to Chapter 10 2 Scanner ID A scanner ID is a unique serial number assigned to an individual scanner at the time of shipment It consists of six numerals 3 Pr...

Page 52: ...Four bytes long and consist of ASCII characters 00h to FEh Code ID mark Type4 Note2 Code type Type1 Type2 Type3 Coupling Separate No Add on A X0 Main A X1 X0 With two digit Add on Add on None X1 Main...

Page 53: ...th C D with C D not transmitted 0 Enabled without C D 1 Enabled with C D with C D transmitted CODE39 CODE39 Full ASCII 3 Enabled with C D without C D transmitted 0 Enabled without C D 1 Enabled with C...

Page 54: ...r system character S automatically disables the transmission of the padding character 0 The conversion to the GTIN format is selectable For the GTIN format conversion refer to Section 9 5 Conversion t...

Page 55: ...Code ID mark Type 4 and Code ID mark output mode Separating For details about the code ID mark refer to 5 Code ID mark The conversion to the GTIN format or to the UPC A are selectable For the GTIN fo...

Page 56: ...ferred to the host EAN 13 with add on A code ID mark precedes add on code data under the conditions Code ID mark Type 4 and Code ID mark output mode Separating For details about the code ID mark refer...

Page 57: ...p codes will be transmitted CODABAR NW 7 The scanner transmits code data read including the start stop codes You can select whether or not to transmit start stop codes CODE128 GS1 128 EAN 128 The scan...

Page 58: ...Conversion to 16 digit GTIN format AI 01 and PI added 0 1 PI 0 S X1 X2 X3 X4 X5 X6 X7 X8 X9 X10 C D 1 1 Check digits are calculated again and transferred regardless of the transmission specified Conv...

Page 59: ...1 PI 0 S X1 X2 X6 0 0 0 0 X3 X4 X5 C D X7 X8 1 X6 3 0 1 PI 0 S X1 X2 X3 0 0 0 0 0 X4 X5 C D X7 X8 1 X6 4 0 1 PI 0 S X1 X2 X3 X4 0 0 0 0 0 X5 C D X7 X8 1 X6 5 9 0 1 PI 0 S X1 X2 X3 X4 X5 0 0 0 0 X6 C D...

Page 60: ...1 PI P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C D X10 X11 1 With 5 digit add on 0 1 PI P1 P2 P3 X1 X2 X3 X4 X5 X6 X7 X8 X9 C D X10 X11 X12 X13 X14 1 1 Check digits are calculated again and transferred reg...

Page 61: ...d again and transferred regardless of the transmission specified Conversion to 14 digit GTIN format PI added With 2 digit add on PI 0 0 0 0 0 P1 P2 X1 X2 X3 X4 C D X5 X6 2 With 5 digit add on PI 0 0 0...

Page 62: ...Check digits are calculated again and transferred regardless of the transmission specified If the transmission of a code ID mark is enabled in the scanner the code ID mark of EAN 13 is transferred Con...

Page 63: ...action mode Data conversion mode Data editing mode Block sorting mode Chapter 7 Section 7 2 Enabled Double read prevention Range of time duration 0 1 to 9 9 sec 0 3 sec Chapter 4 Normal black white co...

Page 64: ...1 9 9 sec 2 0 sec ACK NAK response confirmation time 0 1 9 9 sec 1 0 sec Chapter 9 Section 9 1 1 Scanner ready mode RTS signal control mode Data ready mode Chapter 9 Section 9 1 2 4 USB COM Interface...

Page 65: ...sh 102 keyboard Italian 102 keyboard Swedish 102 keyboard Keyboard type Japanese 106 keyboard Chapter 9 Section 9 3 2 Inboard numeric keys Numeric data 0 9 transmission mode Numeric keypad Chapter 9 S...

Page 66: ...d to the host can be selected When the special key transmission is designated data characters from E7h to FDh in the transmission data are substitution rule tabled below before they are transmitted Da...

Page 67: ...excl UPC EAN Disabled Chapter 9 Section 9 4 6 Enabled Prefix transmission Disabled Enabled Suffix transmission Disabled Chapter 9 Section 9 4 3 Enabled Scanner ID output Disabled Chapter 9 Section 9 4...

Page 68: ...tem Parameter Default Reference None STX Header User defined None ETX CR LF CR LF Terminator User defined Chapter 9 Section 9 4 1 Enabled BCC transmission Disabled Chapter 9 Section 9 4 These can be s...

Page 69: ...eter Default Reference None STX ETX CR LF CR LF TAB ESC ENTER ENTER Right CTRL Header User defined None STX ETX CR LF CR LF TAB ESC ENTER ENTER Right CTRL Terminator User defined Chapter 9 Section 9 4...

Page 70: ...d Transmission of EAN 13 country code Disabled Chapter 9 Section 9 4 NOTE 1 Enabled Conversion to EAN 13 ISBN ISSN format Disabled Enabled Reading UPC E Disabled Enabled C D transmission of UPC E Disa...

Page 71: ...of 5 Disabled Chapter 9 Section 9 4 Minimum number of readable digits for Interleaved 2 of 5 4 digits Maximum number of readable digits for Interleaved 2 of 5 4 to 99 digits 99 digits NOTE 1 NOTE 1 Th...

Page 72: ...setting range is not equal to the number of Scanner s readable digits CODE39 Item Parameter Default Reference Enabled without C D Enabled with C D Reading CODE39 Disabled Chapter 9 Section 9 4 Enable...

Page 73: ...number of Scanner s readable digits 2 With the barcode menu CODE128 GS 128 EAN 128 will be enabled disabled at the same time CODE93 Item Parameter Default Reference Enabled Reading CODE93 Disabled Min...

Page 74: ...S1 DataBar Expanded NOTE 1 Disabled Enabled Reading GS1 DataBar Expanded Stacked NOTE 2 Disabled Convert to GS before Transmission FNC1 transmission of GS1 DataBar Expanded Disabled Minimum number of...

Page 75: ...r 6 Section 6 3 Normal Auto off mode setting One shot Chapter 6 Section 6 1 1 sec 2 sec 3 sec 4 sec Auto off mode one shot ON duration 5 sec Chapter 6 Section 6 1 High Medium Auto sensing bar code det...

Page 76: ...kHz Short 60 msec Medium 80 msec Beeper sound duration Long 120 msec High Medium Beeping volume level Low Chapter 8 Section 8 1 Single beep Reading confiemation sound Multiple beeps Enabled Beeping a...

Page 77: ...mission of result when verification is NG Transmit NG Enabled Retry of verification after NG result 2 poin verification only Disabled Code type barcode data Verification range Barcode data only Chapte...

Page 78: ...ion AI1 Select from candidate AIs NOTE 2 00 AI split mode AI selection AI2 Select from candidate AIs NOTE 2 00 AI split mode AI selection AI3 Select from candidate AIs NOTE 2 00 Header Terminator Comm...

Page 79: ...er to scan the Start setting Barcode symbol Three beeps Scan parameter setting Barcode symbols Scan necessary parameter setting Barcode symbols End setting Scan the End setting Barcode symbol Three be...

Page 80: ...per volume can be set by reading the following Barcode symbol only No Start setting or End setting Barcode symbol required to be scanned Adjusting the beeper volume Reading this Barcode symbol cycles...

Page 81: ...ications parameters for RS 232C interface Procedure No protocol mode ACK NAK mode Transmission speed 4800bps 9600bps 19200bps 38400bps 57600bps 115200bps Data bit 7bits 8bits Parity None Odd parity Ev...

Page 82: ...71 Stop bit 1 bit 2 bits CTS signal monitoring Not controlled Controlled Header None STX Terminator ETX CR LF CR LF None Transmission of BCC Disable Enable...

Page 83: ...72 Communications parameters for USB COM interface Procedure No protocol mode ACK NAK mode CTS signal monitoring Not controlled Controlled Header None STX Terminator ETX CR LF CR LF None...

Page 84: ...73 Transmission of BCC Disable Enable...

Page 85: ...USB keyboard interface Caps Lock mode Manual OFF Manual ON Auto Keyboard type U S English 101 Keyboard Germany 102 Keyboard French 102 Keyboard U K English 102 Keyboard Italian 102 Keyboard Swedish 10...

Page 86: ...75 Data trasmission interval 1ms 5ms 10ms 15ms 30ms 50ms 100ms Numeric data transmission format Inboard numeric keys Numeric keypad Special key transmission mode Enable Disable...

Page 87: ...76 Header USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...

Page 88: ...77 Terminator USB keyboard interface None STX ETX CR LF CR LF TAB ESC ENTER Right Ctrl...

Page 89: ...78 Data transmission format Transmission of code ID mark Enable Disable Tranmission of the number of digits Enable in 4 digits Enable in 2 digits Disable...

Page 90: ...able Reading UPC EAN add on Enable in 2 digit add on Disable in 2 digit add on Enable in 5 digit add on Disable in 5 digit add on Standard 2 of 5 Reading Standard 2 of 5 Enable without a chek digit En...

Page 91: ...of 5 Enable without a chek digit Enable with a check digit Disable Check digit transmission Enable Disable CODABAR NW 7 Reading CODABAR NW 7 Enable without a check digit Enable with a check digit Disa...

Page 92: ...op codes for CODABAR NW 7 Transmit a b c d Transmit A B C D Disable CODE32 Conversion from CODE39 to CODE32 Enable Disable Transmission of the leading A of CODE32 Enable Disable Check digit confirmati...

Page 93: ...hout a check digit Enable with a check digit Disable Check digit transmission Enable Disable Transmission of start stop codes for CODE39 Enable Disable Conversion to CODE39 Full ASCII Enable Disable C...

Page 94: ...of CODE128 Convert to GS before transmission Disable FNC1 transmission of GS1 128 EAN 128 Convert to GS before transmission Disable MSI Reading MSI Enable without a check digit Enable with a check dig...

Page 95: ...ading type of Plessy Dual Single GS1 DataBar RSS Reading GS1 DataBar Omnidirectional GS1 DataBar Truncated Enable Disable Reading GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Enable Disable...

Page 96: ...85 Reading GS1 DataBar Expanded Enable Disable Reading GS1 DataBar Expanded Stacked Enable Disable FNC1 transmission of GS1 DataBar Expanded Convert to GS before transmission Disable...

Page 97: ...switching mode Momentary switching mode Reverse type Alternate switching mode Continuous reading mode 1 Continuous reading mode 2 Auto sensing mode Auto stand mode Auto off reading mode setting Norma...

Page 98: ...87 Auto sensing barcode detection level High Medium Low...

Page 99: ...88 Beeper Indicator LED Beeper control Enable Disable Beeper frequency Low Medium High Beeper sound duration Short 60ms Medium 80ms Long 120ms LED indicator Enable Disable...

Page 100: ...way from the barcode and try again Setting Trouble Cause Countermeasure The type of the barcode to be scanned has not been set as a readable code Enable the type of the barcode to be scanned as a read...

Page 101: ...ate selected not match that of the connected keyboard Select the same Caps Lock state as that of the connected keyboard Any device driver other than the system supplied driver USB device class driver...

Page 102: ...ach 6surface x 10times on the concrete Note2 Note3 Note4 Electrostatic durability IEC61000 4 2 LEVEL Special Note2 Note3 Note4 dirct dischage indirect dischage 6kV Trigger switch operation Operation 1...

Page 103: ...ction Z Note1 READOFF LOFF Reading standby Only when the trigger switch is set to continuous reading mode 1 or 2 the scanner will enter the reading standby state by receiving Z READOFF or LOFF command...

Page 104: ...esponse from the scanner er n nn mm n nn Firmware version No mm Setting parameter Version No Example Ver 1 00 00 E Scan entry remote request When performing n point verification reading the system ent...

Page 105: ...to standby before reading a set of split Barcode symbols the duplication prevention processing will be canceled The code data that has been read halfway will be discarded The READOFF and LOFF command...

Page 106: ...m host type only Power supplied from AC adapter Power supplied from host Pin Signal 1 N C N C 2 TxD TxD 3 RxD RxD 4 Shorted wit 6 N C 5 GND GND 6 Shorted wit 4 N C 7 CTS CTS 8 RTS RTS 9 N C 5VDC Pin S...

Page 107: ...96 USB interface TypeA USB connector Viewed from pin side Pin Signal 1 5VDC 2 D 3 D 4 GND 4 2 1 3...

Page 108: ...Barcode Handy Scanner AT20B SM AT21B SM User s Manual First Edition November 2011 DENSO WAVE INCORPORATED...

Page 109: ...1 Yoshiike Kusagi Agui cho Chita gun Aichi 470 2297 Japan http www denso wave com...

Reviews: