27
3. CD HEAT RUN MODE
(1) AC is turned on.
(2) Press the
5
button to open the tray.
(3)Set a disc on the tray, then press the
5
button again to close the tray.
(4) AC is turned off.
(5) AC is turned on while pressing the
5
and
2
button same time on this unit.
(6) Switches to mode according to button input.
(7) Press the reverse button to switch the mode while displaying the version of the main μcom.
(Normal heat run mode, Heat run short mode, Heatrun chacking mode.)
(8) If an error occurs, display the error and stop operation at that point.
(9) Number of operations held.
(10) While heat run, the operation of each button is not valid except the POWER button and pressing the
5
and
2
button same time.
3.1. Normal heat run mode
(1) Press the
1
/
3
button while name of the model is displayed or H.R.NORMAL is displayed.
(2) Count this as the 0th heat run repetition.
q
Play the last track only on disc.
Normal display except when
1
light,
3
flashing.
w
After disc playback has finished, move pickup to innermost position and open tray.
(XXXX : No. of heat run repetitions)
e
When loader open status detected, close tray again, re-read TOC and start playback from the first track on the
disc.
Normal display except when
1
light,
3
flashing.
r
The heat run repetition no. is incremented (increased by 1) when the tray is opened.
※
If the
2
and
5
button is pressed while operating, number of heat run is displayed for 3 seconds
※
Press the
2
button, then press the
5
button.
.
(XXXX : No. of heat run repetitions)
t
Conduct
q
to
e
repeatedly.
H.R.NORMAL
CD
XXXX
CD
XXXX
Summary of Contents for DCD-F109
Page 32: ...32 Personal notes...
Page 57: ...57 PACKING VIEW 6 1 4 5 3 2 6 9 11 10 8 9 10 5 7 5 6 5 8 5 1 5 5 5 5 2 5 3 5 4 s...
Page 63: ...63 TMP92CD28AFG IC15 39 DCD 710AE TMP92CD28AFG IC15...
Page 67: ...67 TC94A92FG IC17 43 DCD 710AE TC94A92FG IC17...
Page 75: ...75 2 FL DISPLAY V F D 16 ST 103GINK FLT500 PIN CONNECTION GRID ASSIGNMENT 1 43...
Page 76: ...76 GRID ASSIGNMENT...
Page 77: ...77...