PROCEDURE AFTER REPLACING THE PCB.
PROCEDURE AFTER REPLACING THE U-COM, ETC.
The firmware of U4 (EN25QH16B-104HIP2A) in the MAIN PCB differs depending on the region.
Be sure to follow the instructions in "
" to update to the latest firmware
after changing a circuit board.
The procedure after replacing the u-COM (microprocessor), flash ROM, etc. is as follows.
PCB Name Ref. No.
Description
Procedure
after Re-
placement
Remark
MAIN
U4
EN25QH16B-104HIP2A 16Mb
B
SOFTWARE : DSP
MAIN
U10
STM32F030R8T6
B
SOFTWARE : Main
Procedure after Replacement
A :
The software has been written. The software is not written at the time of replacement.
B :
The software has been written. The software may need to be rewritten by version updates. Check the
version.
C :
The software has not been written. The software needs to be written after replacement.
See "
" for information on writing the software.
D :
The software has been written. Be sure to rewrite with the latest software for your service region.
" for information on rewriting the software.
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating