3-4. Error Code H1-15 failure detection procedure
Checking device. [
IC732 : MX25L3206EMI(E3, E1C, K)/MX25L6406EMI(E2)
]
Check item(17).
Write to the OSD ROM.
Recheck from
check item (1)
Does Error Code H1-15 continue?
Check item(18).
Replace [
IC732
] with a new device.
Recheck from
check item (1)
Does Error Code H1-15 continue?
Go to
check item (12)
Recheck from
check item (2).
YES
YES
NO
NO