DAEnetIP4
SNMP Five Channel Relay Module
- User's Manual
08 Aug 2017
-16-
6.
Loading the default (factory) settings
When necessary, the factory (default settings) may be applied so the
DAEnetIP4
parameters will be loaded back.
Figure 21.
System port JP5
When
DAEnetIP4
is shipped from the factory, the jumper is placed on JP5 pins 2
and 3.
1. Turn off the power supply of the device;
2. Move the jumper to the
Default Position
(between pin 1 and 2);
3. Turn on the power supply of the device;
4. Wait until the status led become ON (approximately 10 sec);
5. Remove the jumper from the
Default Position
;
6. Turn off the power supply of the device;
7. Move back the jumper to the middle position (between pin 2 and 3);
8. The module is configured with default settings.
In order to do this procedure in BOX version, you have to remove the top
part of the housing before that!