background image

 

DEMA SINGLE-FEED 

MODEL: 651GAP, 651GAP-1 & 651GAP-1M 

INSTALLATION INSTRUCTIONS

 

I-781 

 

 

Pg. 1 of 6 

Rev. G-42173                                                                      10/04/16

 

 
 

The Model 651GAP is designed to dispense one product into a kitchen sink with the turn of a ball valve. 

 

I. PARTS:

 

 

ITEM DESCRIPTION 

QTY. 

   A 

Dispenser Assembly 

½” ID X 6’ Long Vinyl Outlet Tubing (For 4 GPM Station Only) 

¼” ID X 8’ Long Vinyl Supply Tubing 

D Foot 

Valve 

E Ceramic 

Weight 

#10 Screws & Anchor Kit 

Metering Tip Kit 

 

 

 

 

II.

 

INSTALLATION:

  (See Figure 1 for setup diagram) 

 

This product is designed only to be used as described in this instruction sheet.  Adhere to all warnings and 
cautions identified in this document.   

 

WARNING: 

Installations must conform to all local and national plumbing codes and use 

approved backflow prevention and pressure relief devices where required. 
 

ALWAYS DISCONNECT DISPENSER FROM WATER SOURCE WHEN DISPENSER 
IS NOT IN USE. 

 

Always read SDS for all chemicals used and follow personal protective guidelines.

 

 

A.  Mounting and Water Supply: 

Locate mounting holes on a permanent surface above sink. The unit needs to be mounted high enough that the sink does not 
interfere with the outlet tube, putting a strain on the proportioner.  Drill all holes into the drywall using a ¼” diameter bit for 
use with the included #10 screw & anchor set.  (If mounting dispenser to wood and you do not plan to use the anchors, drill 
1/8” diameter holes 1” deep.)  Insert the anchors into drilled holes and hammer them into the wall until they are flush with 
face of wall.   Assemble all of the #10 screws with a Phillips screwdriver into the anchors so the screw heads are sticking 
out of the wall approximately 1/8”.  Mount the unit by inserting the screw heads through the keyhole slots and tighten the 
screws.  Secure unit by inserting screws into the lower 2 holes. 
 
The water inlet is equipped with a female garden hose fitting (with strainer washer) for attaching a water supply hose.  The 
water inlet may be removed to permit direct connection to a 1/4" NPT pipe.  The unit is designed so water can be supplied to 
either side by interchanging the pipe plug with the water inlet assembly.  
 

Note:  Apply pipe dope, hand tighten, then turn 1-½ times with a wrench. 

 

Do not over tighten. 

 

  

B. Chemical 

Supply: 

Place the chemical container in a convenient location not more than 6 ft. below the dispensing unit.  

Note: greater lifts will 

reduce injection capacities.

  Slip a ceramic weight over the chemical supply tubing and insert the foot valve end of the 

tubing into the chemical container.  Cut the vinyl tube to any convenient length that will allow the tube to extend from the 
bottom of the chemical container to the proportioner inlet barb.  Install the other end of the tubing by pushing tubing over 
proportioner inlet barb.   
 

C. Outlet 

Tubing: 

For the 4 GPM proportioner outlet: Cut a piece of the ½” I.D. outlet tubing to the desired length and attach to the 
proportioner outlet barb.  

Do not force tubing onto the larger barbs on the proportioner. 

 

Note: Outlet tube may be 

anchored to the wall or faucet to prevent damage to the proportioner. 
 
Caution

:  

To prevent continuous siphoning, the outlet of the discharge tubing should not be below the level of 

chemical in the container.

  

 