VFD-C2000 PROFINET Communication Card CMC-PN01
CMC-PN01
Operation Manual
15
way of communication.
4
LSB
VFD
Fault/Control
Command
2002h
W
b0
1:EF (external fault) ON
External Fault (EF) enabled
1. This bit is used for triggering an
external fault to VFD to stop the running
status. The method for stopping can be
set by VFD parameter.
2. This bit operates by on-shot method
and this fault can only be restored by
Fault Reset command.
b1
1: Reset
Fault Reset command
This bit is used for resetting the status
from Fault to Ready.
b2
1: b.b. ON
External B.B. (Base Block)
enabled
This bit is used for triggering an external
B.B. to VFD to pause the running status.
When bit=0 (BB is dismissed), VFD
immediately returns to its former status.
b3
1: HAND-ON/LOC-ON command
HAND/LOCAL frequency
operation source enabled
Whether switching HAND/AUTO or
LOC/REM would lead to running STOP
depends on motor drive
’s parameter
settings.
b4
1: AUTO-ON/REM-ON command
AUTO/REMOTE frequency
operation source enabled
5
MSB
b15
–b5
Not used
6
LSB
2003h
W
b15
–b0
Reserved
Reserved
Reserved
7
MSB
8
LSB
2004h
W
b15
–b0
Reserved
Reserved
Reserved
9
MSB
10
LSB
2005h
W
b15
–b0
Reserved
Reserved
Reserved
11
MSB
12
LSB
2006h
W
b15
–b0
Reserved
Reserved
Reserved
13
MSB
14
LSB
2007h
W
b15
–b0
Reserved
Reserved
Reserved
15
MSB
16
LSB
2008h
W
b15
–b0
Reserved
Reserved
Reserved
17
MSB
18
LSB
2009h
W
b15
–b0
Reserved
Reserved
Reserved
19
MSB
Table 4: 21xx Input Message (Drive
Host Controller) (Pr.09-30=0)
Bytes
Order
Command
Address
Attribute
Value
Definition
Description
0
LSB
Fault
Status
2100h
R
b7
–b0
Error Code
Fault codes
Bits in this column are used for checking if VFD
occurs any fault, and using the fault codes to
substitute 32XXh to obtain the description strings for
the fault.
1
MSB
b15
–b8
Warn Code
Warning
codes
Bits in this column are used for checking if VFD
occurs any warnings, and using the warning codes to
substitute 33XXh to obtain the description strings for
the fault.
2
LSB
Operation
Status
2101h
R
b1
–b10
00: RUN LED light off, STOP LED
light up (Drive Stop)
Run and stop
status
Bits in this column are used for checking VFD
’s
running status in order to control its LED display.
01: RUN LED blink, STOP LED light
up (Drive Decelerate during the
drive stopping)
10: RUN LED light up, STOP LED
blink (Drive standby)
11: RUN LED light up, STOP LED
light off (Drive Run)
b2
1: JOG active
JOG running
status
b4
–b3
00: REV LED light off, FWD LED
light up (Forward)
Operation
direction
status
Bits in this column are used for checking VFD
’s
running direction status in order to control its LED
display.
01: REV LED blink, FWD LED light
up (Reverse to Forward)
10: REV LED light up, FWD LED
blink (Forward to Reverse)
11: REV LED light up, FWD LED
light off (Reverse)
b5
1: Factory parameters opened
Factory
parameter
ON/OFF
status (not
used)
b6
Reserved
b7
1: Operation command controlled by
external terminal
Bits in this column are used for checking whether
VFD
’s current operation command source is external
terminal or not. If bit=1, external terminal has the
highest processing priority. Master communication
can obtain control rights only when it switches
operation command source by 2000h b14
–13.
3
MSB
b8
1: Main Freq. controlled by
communication
Bits in this column are used for checking the current
VFD frequency command source.
b9
1: Main Freq. controlled by external
terminal (AI)
b10
1: Operation command controlled by
Communication
Bits in this column are used for checking whether the
current VFD operation command source are
communication or not.
b11
1: Parameters been locked
Parameter
Lock ON/OFF
status
Bits in this column are used for checking whether
VFD
’s parameters are locked or not. If bit=1, the
values for reading parameters are always 0.
b12
0: AC drive stop, 1: AC drive run
VFD actual
running output
status
(RUNNING=1)
b13
Jog command
JOG running
Summary of Contents for VFD-C2000
Page 1: ...VFD C2000 PROFINET Communication Card Operation Manual 20181106...
Page 24: ...VFD C2000 PROFINET Communication Card CMC PN01 CMC PN01 Operation Manual 24...
Page 27: ...VFD C2000 PROFINET Communication Card CMC PN01 CMC PN01 Operation Manual 27...
Page 28: ...VFD C2000 PROFINET Communication Card CMC PN01 CMC PN01 Operation Manual 28...