background image

Delta VF-MD drive short manual for encoder model 

Drive I/p connections:      L1- PHASE, L2-NEUTRAL 

Drive o/p connections:      U, V, W TO MOTOR 

Control terminals:  DCM-door common signal 

                                  REV- door open signal 

                                  FWD-door close signal 

Encoder terminals: VP-red wire, black-DCM, yellow-A, blue-B (put dip 
switch in +12v mode) .this switch near to VP terminal. 

Door feedback signals: Door close limit signal-RC1 (com), RB1 (NC), RA1 
(no), Door open limit signal-RC2 (com), RA2 (no) 

Drive program:    

User parameters: 

 0-17-30 %( vary depend on site) , 0-18-1 

Basic parameters: 

1-00-50.0, 1-01-50.0, 1-02-220volts,1-07-6.0 

Motor and feedback parameters: 

2-02-0.2(put first), 2-01-0.58, 2-04-6, 2-11-50, 2-12-1, 2-13-450, 2-14-50, 2-
18-20 

Motor auto tuning –put 0-12-0, then press run command for auto tuning.  

 After this check motor direction by press run command door should close 
.if direction reverse interchange two motor wires and repeat motor tuning 
again 

Door open control parameters: 

3-00 -6, 3-01-20, 3-02 -20, 3-03 -90, 3-04-6.0, 3-05-95, 3-06-4.0, 3-12-20, 

 3`-17-999.9 

 

Reviews: