1.  Safety Instructions 

 

Must select correct AC input voltage before turning on (Refer to Fig. 1). 

 

The device is not recommended to be placed on low thermal conductive surface. For example, 

plastics. 

 

For safety reasons, please ensure the mounted device is kept at 

 

4mm safety distance at all sides 

from other components and equipments. In addition, to ensure sufficient  convection cooling, 

always maintain a distance of ≥ 20mm from fan ventilated surfaces while the device is in operation.

 

Please insert an insulation sheet between the system and product, if the safety distance is < 4mm 

(Refer to Fig. 3). 

 

Note that the enclosure of the device can become very hot depending on the ambient temperature 

and load of the power supply. Do not touch the device while it is in operation or immediately after 

power is turned OFF. Risk of burning! 

 

Do not touch the terminals while power is being supplied. Risk of electric shock. 

 

Prevent any foreign metal, particles or conductors from entering the device through the openings 

during installation. It may cause: - Electric shock; Safety Hazard; Fire; Product failure. 

 

Warning: When connecting the device, secure Earth connection before connecting L and N. When 

disconnecting the device, remove L and N connections before removing the Earth connection. The 

power supply must be mounted by metal screws onto a grounded metal surface. It is highly 

recommended that the Earth terminal on the connector be connected to the grounded metal 

surface.

 

 

2.  Device Descriptions 

Refer to Fig. 1.:

 

 

1     Input & Output terminal block connector 

2

 

DC voltage adjustment potentiometer 

DC OK control LED (Green)  

AC selectable switch 

 

3.  Installation of the Device 

A      Side Mounting: 

Fig.  2  and  Fig. 

3  show the mounting hole locations for power supply 

assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 

4 mounting holes using M4  screw of maximum  5mm  length  (Refer to Fig. 5).  This is to 

maintain a safety distance between the screw and internal components. 

B      Base Mounting: 

Fig.  2  and  Fig. 

3  show the mounting hole locations for power supply 

assembly onto a metal mounting surface. The power supply shall be mounted on minimum of 

4 mounting holes using M4 screw of maximum  4mm  length  (Refer to Fig. 5).  This is to 

maintain a safety distance between the screw and internal components. 

C      

Fig. 2: 

Connector  

D      

Fig. 2: 

This surface belongs to customer’s end system or panel where the device is mounted. 

 

 

Use flexible cable (stranded or solid) with the following sizes: 

Output Voltage 

4.2

-5V 

12V

 

24V

 

36-48V 

Wire Size 

AWG 14-

12

 

AWG 16-

12

 

AWG 20

-

12

 

AWG 22

-

12

 

The input/output connectors’ all

owable  current  is  2

3A max per pin. User should calculate and 

select the suitable wire specification (type/quantity/diameter) according to actual output current. 

The torque at the connector shall not exceed 13Kgf.cm. The insulation stripping length should not 

exceed 0.275” or 7mm (Refer to Fig. 

4). 

 

Recommended mounting torque of the product and its mounting accessories is 

9~12Kgf.cm.

 

 

4.  Installation of Mounting Accessories 

 

Please refer to the requirements in section 3 for 

the “Installation of the Device”

 

PMT-

V350W1A

 

Fig. 4. Wire Type

 

Lug 

Stripped wire 

Fig. 5. Assembly Reference

 

Safety Distance 
D1 = 4.0mm Min. 

D2 = 20.0mm Min. 

Fig. 3. Mounting Hole Locations and the Safety Distance

 

Base Mounting (Horizontal) 

Base Mounting (Vertical) 

Side Mounting (Horizontal) 

Fig. 2. Mounting Orientations

 

Fig. 1. Device Descriptions 

PMT-24V350W1AG, PMT-

V350W1AK,  

PMT-

V350W1AN 

(Front Face Terminal Block)

 

PMT-

V350W1AM, PMT-

V350W1AR 

(Standard Terminal Block)

 