1.  Safety Instructions

• 

To ensure sufficient convection cooling, always maintain a safety distance of 

≥ 20mm from all ventilated surfaces while the device is in operation.

• 

The  device  is  not  recommended  to  be  placed  on  low  thermal  conductive 

surface, for example, plastics.

• 

Note that the enclosure of the device can become very hot depending on the 

ambient temperature and load of the power supply. Do not touch the device 

while it is in operation or immediately after power is turned OFF. Risk of burning!

• 

Do not touch the terminals while power is being supplied. Risk of electric shock.

• 

Prevent any foreign metal, particles or conductors to enter the device through 

the openings during installation. It can cause: Electric shock; Safety Hazard; 

Fire; Product failure

• 

Warning:  When  connecting  the  device,  secure  Earth  connection  before 

connecting  L  and  N.  When  disconnecting  the  device,  remove  L  and  N 

connections before removing the Earth connection.

2.  Device Descriptions

Refer to Fig. 1.:

 

Input & Output terminal block connector

 

DC voltage adjustment potentiometer

 

DC OK control LED (Green)

3.  Installation of the Device

Refer to Fig. 2.: 

 

Mounting  holes  for  power  supply  assembly  onto  the  mounting  surface.  The 

power supply shall be mounted on minimum 2 mounting holes using M3 screw 

minimum 5mm length.

 

This  surface  belongs  to  customer’s  end  system  or  panel  where  the  power 

supply is mounted.

 

Connector

• 

Use flexible cable (stranded or solid) with the following sizes: 

Standard Connector

IP20 Connector

AWG 18-14

AWG 18-12

• 

The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping 

length should not exceed 0.275” or 7mm (Refer to Fig. 3).

4.  Installation of Mounting Accessories

Refer to Fig. 4.:

• 

Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a 

safety distance between the screw and internal components.

• 

Recommended mounting tightening torque: 4~8 Kgf.cm.

REV.02

Ventilated Surface

Side Surface

Top Surface

Base Surface

1

2

3

A

B

A

B

A

C

C

C

B

A

B

A

B

A

C

C

C

B

A

B

A

B

A

C

C

C

B

Fig. 1. Device Descriptions

Standard Connector

IP20 Connector

Fig. 3. Wire Type

Fig. 4. Mounting Screw

Lug

Stripped wire

Mounting

accessories

Mounting

screw

Chassis of 

the device

6mm max.

7 mm

Fig. 2. Mounting Orientation

Side Mounting (Vertical)

Base Mounting (Vertical)

Side Mounting (Horizontal)

1

2

3

Ventilated Surface

Side Surface

Top Surface

Base Surface

Summary of Contents for PMC-24V150W1A Series

Page 1: ... 䐡 DC OK control LED Green 3 Installation of the Device Refer to Fig 2 䑵 䑵 Mounting holes for power supply assembly onto the mounting surface The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length 䑶 䑶 This surface belongs to customer s end system or panel where the power supply is mounted 䑷 䑷 Connector Use flexible cable stranded or solid with the following...

Page 2: ...使用说明书 1 安全上の注意 電源装置を十分に冷却するため 運転中はすべての通気面の周囲に 20 mm 以 上のスペースを保って下さい 本装置を低熱伝導面 例 プラスチック に設置することは避けて下さい 電源装置の周囲を囲うと 周囲温度や電源の負荷によって非常に熱くなるこ とがありますので注意して下さい 電源装置の運転中やパワーをオフにした 直後は 装置に触れないで下さい やけどの恐れがあります 電源運転中はターミナルに触らないで下さい 感電の危険があります 装置を箱から出してから設置するまでの間 金属の異物や導電体が装置の中 に入らないようにして下さい こうした異物は 感電 火事 装置の故障を 引き起こす危険があります 警告 電源装置の配線時 L と N をつなぐ前にアースにつなぐこと 装置を はずす際 アース接続をはずす前に L と N の接続をはずすこと 2 電源装置の各部名称 図 ...