background image

Instruction Manual

PMC-05V015W1A

www.DeltaPSU.com

1.  Safety Instructions

• 

To ensure sufficient convection cooling, always maintain a safety distance of    

≥ 20 mm from all ventilated surfaces while the device is in operation.

• 

The  device  is  not  recommended  to  be  placed  on  low  thermal  conductive 

surface, for example, plastics.

• 

Note that the enclosure of the device can become very hot depending on the 

ambient temperature and load of the power supply. Do not touch the device 

while it is in operation or immediately after power is turned OFF. Risk of burning!

• 

Do not touch the terminals while power is being supplied. Risk of electric shock.

• 

Prevent any foreign metal, particles or conductors to enter the device through 

the openings during installation. It can cause: Electric shock; Safety Hazard; 

Fire; Product failure

• 

Warning:  When  connecting  the  device,  secure  Earth  connection  before 

connecting  L  and  N.  When  disconnecting  the  device,  remove  L  and  N 

connections before removing the Earth connection.

2.  Device Descriptions

Refer to Fig. 1.:

 

Input & Output terminal block connector

 

DC voltage adjustment potentiometer

 

DC OK control LED (Green)

3.  Installation of the Device

Refer to Fig. 2.: 

Mounting holes for power supply assembly onto the mounting surface. 

 

The power supply shall be mounted on minimum 2 mounting holes using M3 

screw minimum 5 mm length.

 

The power supply shall be mounted on minimum 2 mounting holes using M3 

screw only. The screw penetration into the chassis must be ≤ 2 mm.

 

Connector

 

This  surface  belongs  to  customer’s  end  system  or  panel  where  the  power 

supply is mounted.

• 

Use flexible cable (stranded or solid), AWG no. 20-16. Recommended torque 

at the connector shall be 5 Kgf.cm. The insulation stripping length should not 

exceed 0.275” or 7 mm (Refer to Fig. 3).

4.  Installation of Mounting Accessories

• 

Only use M3 screw ≤ 2 mm through the base mounting holes. This is to keep a 

safe distance between the screw and internal components.

• 

Refer to Fig. 4.:

Recommended mounting tightening torque: 4~8 Kgf.cm

Fig. 1. Device Descriptions

1

2

3

Top surface

Side surface

Ventilated surface

Base surface

Fig. 1. Device Descriptions

Fig. 2. Mounting Orientation

A

A

B

C

C

C

D

D

D

A

A

B

C

C

C

D

D

D

A

A

B

C

C

C

D

D

D

Side Mounting (Vertical)

Base Mounting (Vertical)

Side Mounting (Horizontal)

REV.03

Fig. 3. Wire Type

Fig. 4. Mounting Screw

Lug

Stripped wire

7mm.

Mounting

accessories

Mounting

screw

Chassis of 

the device

2mm max.

Reviews: