background image

TECHNICAL DATASHEET

 

PJB Open Frame Power Supply 

24V 100W 1 Phase / PJB-24V100W

□□

A

 

 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (October 2020, Rev. 03)  

 

1

 

PJB  

Highlights & Features 

  Universal AC Input (85Vac – 264Vac) 

  Power Boost of 200% for 10 seconds 

  Low Inrush Current / Low Leakage Current 

  High efficiency and PF factor to conserve energy 

  Conformal coating on PCBA to protect against chemical and 

dust pollutants 

  Remote ON/OFF (Optional for 100W) 

  Versatile configuration options: Open Frame, L Frame, 

Enclosed 

  Long life capacitors 

 

Safety Standards 

 

CB Certified for worldwide use 

 

Model Number:

   

PJB-24V100W

☐☐

Unit Weight:

 

 

Open Frame

: 0.26 kg (0.57 lb) 

   

 

 

Enclosed

: 0.42 kg (0.93 lb) 

Dimensions (L x W x D):

 

Open Frame

155 x 62 x 33.5 mm  

(6.10 x 2.44 x 1.32 inch) 

   

 

 

Enclosed

185 x 72 x 45 mm  

(7.28 x 2.83 x 1.77 inch) 

General Description 

The PJB series of Open Frame Power Supply comes with universal AC input at 85Vac to 264Vac. Other features include low leakage / 

Inrush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants. The built-in active PFC 

provides PF > 0.97 and fulfills Harmonic Current Emission according to IEC/EN 61000-3-2. The feature built-in Power Boost of 200% for 

10 seconds enables reserve power to be always available for reliable startup of loads with high inrush current, thus eliminating the need 

of a more expensive power supply unit at higher power rating. Metal chassis and case cover are available as options for different 

installation preferences.  

 

The PJB series is certified for EMI standards according to EN 55032 and EMS according to EN 55024. The products conform to major 

international safety standards according to EN/UL 62368-1 standards and are fully compliant with RoHS Directive for environmental 

protection.  

 

Model Information 

PJB Open Frame Power Supply 

 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

PJB-24V100W

☐☐

A

 

85-264Vac 

24Vdc 

4.30A 

 

Model Numbering 

 

 

 

 

CC Code 

 

PJB –

 

24V

 

100W

 

 

 

A

 

PJB Series 

Output Voltage  Output Power  Package Type 

B - Open Frame 

L - L Frame 

C - Enclosed 

Remote ON/OFF Function 

N - No Remote ON/OFF 

R - With Remote ON/OFF 

Delta Standard 

 

 

 

Summary of Contents for PJB-24V100WA

Page 1: ...rush current and conformal coating on the PCBAs to provide protection against dust and chemical pollutants The built in active PFC provides PF 0 97 and fulfills Harmonic Current Emission according to...

Page 2: ...g at 24V 8 60A Power Boost for 10 seconds at 24V refer to the details in the Functions section Output Power 103 2W continuously operating at 24V 206 4W Power Boost for 10 seconds at 24V refer to the d...

Page 3: ...Degree 2 Protections Overvoltage 27 6 33 6V Latch Mode Overload Overcurrent 220 of rated load current Hiccup Mode Non Latching Auto Recovery Over Temperature Latch Mode Short Circuit Hiccup Mode Non...

Page 4: ...4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode2 2kV Differential Mode3 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fiel...

Page 5: ...Connector 3 VR 4 Remote ON OFF JST B2B XH A 5 Chassis Dimensions Open Frame L x W x D 155 x 62 x 33 5 mm 6 10 x 2 44 x 1 32 inch L Frame L x W x D 185 x 72 x 45 mm 7 28 x 2 83 x 1 77 inch Notes Dimens...

Page 6: ...Rev 03 6 Item Device Description 1 Input Connector 2 Output Connector 3 VR 4 Remote ON OFF JST B2B XH A 5 Cover 6 Chassis Enclosed L x W x D 185 x 72 x 45 mm 7 28 x 2 83 x 1 77 inch Notes Dimensions a...

Page 7: ...nce at all sides from other components and equipments Please insert an insulation sheet between the system and product if the safety distance is less than 4mm 0 16 inch Use flexible cable stranded or...

Page 8: ...ting for Mounting Orientation A B 40 C de rate power by 2 5 C De rating for Mounting Orientation C 35 C de rate power by 2 C De rating for Mounting Orientation D E 30 C de rate power by 2 C De rating...

Page 9: ...or be damaged when the power supply is continuously used outside the shaded region refer to the graphs shown above 2 If the output capacity is not reduced when the surrounding air temperature is more...

Page 10: ...t Current mA Output ON Output OFF 1k 5 12 5 0 0 5 20 Max Notes 1 Remote ON OFF circuits are isolated from input output and PE 2 Please check if the polarity of the wire connector is the same as the ex...

Page 11: ...te set value after the input voltage is applied Rise Time The time required for the output voltage to change from 10 to 90 of its final steady state set value Hold up Time Time between the collapse of...

Page 12: ...Power Boost to be longer than the specified duty cycle calculation this may cause damage to the PSU Power Boost is the reserve power available constantly that allows reliable startup to support sudde...

Page 13: ...ustration in the OLP OCP section on this page The power supply will return to normal operation after the short circuit is removed Overload Overcurrent Protections Auto Recovery The power supply s Over...

Page 14: ...nvironment complying with EN 61000 3 2 is only necessary under special conditions Complying to this standard can have some technical drawbacks such as lower efficiency as well as some commercial aspec...