Chapter 3 Featured Function
3-20
Description
Factory Default
Suffix Process
Specify the comparison process for the Suffix Length and Suffix Char.
Include Suffix Char:
The data will transmit all the Suffix Char
which user entered in Suffix Char (Hex.). If the Suffix Length is 1,
then only first Suffix Char will be included.
Only Suffix Char 1:
The data will transmit only Suffix Char 1
which user entered in Suffix Char (Hex.).
Not Include:
After the comparison process is complete, the data
will be transmitted without Suffix Char which the user entered in
Suffix Char (Hex.).
Include Suffix
Char
Aging Time
Specify the time for DVW device to force pack the received serial data
into the same data frame.
Notice:
Before you configure the settings of Aging Time, please
remember check the Enable item, otherwise the Aging Time
doesn’t be applied.
Disable/
1000 (ms)
3.3.1.5
Virtual COM Mode
In Virtual COM mode, DVW device can establish a network connection between the host computer
and serial device. So the DVW device maps the IP address with port number to the serial port on
itself. When the application on host computer doesn’t provide serial interface to connect with serial
device, then Virtual COM mode can solve this problem and establish a Virtual COM connection on
Ethernet interface.
Summary of Contents for DVW SERIES
Page 1: ......
Page 5: ...iv Appendix B MODBUS TCP Map B 1 MODBUS TCP Map B 2 ...
Page 6: ...v ...
Page 14: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 1 8 MEMO ...
Page 100: ...DVW Series Industrial IEEE 802 11 a b g n Wireless AP WDS Client Gateway User Manual 4 12 ...
Page 101: ...Appendix A Private MIB Group Table of Contents A 1 Private MIB Group A 2 A 1 ...
Page 103: ...Appendix B MODBUS TCP Map Table of Contents B 1 MODBUS TCP Map B 2 B 1 ...