background image

TECHNICAL DATASHEET

 

Sync DIN Rail Power Supply 

12V 50W 1 Phase (NEC Class 2) / DRS-12V50W1N

□ 

 
 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (March 2016, Rev. 00)  

 

1

 

 

Highlights & Features 

– 

Ultra-compact size and galvanic isolation up to 3.0KVac 
between input to output and input to ground 

– 

Universal AC input voltage and full power from -10°C to 
+55°C operation 

– 

Up to 89.0% efficiency 

– 

Low earth leakage current < 0.5mA @ 264Vac 

– 

Built-in DC OK relay contact option available 

– 

Extreme low temperature cold start at -40°C 

– 

NEC Class 2 / Limited Power Source (LPS) certified 

 
 

Safety Standards 

 

CB Certified for worldwide use 

 
 

Model Number:

   

DRS-12V50W1N

 

Unit Weight:

 

 

0.18 kg (0.40 lb)  

Dimensions (L x W x D):

  75 x 30 x 89.5 mm

 

 (2.95 x 1.18 x 3.52 inch) 

 
 

General Description 

The ultra-compact and competitively priced Delta Sync DIN Rail DRS-12V50W1N

 power supply is designed for industrial applications 

requiring highly reliable power supply that must fit in a small space. The Sync series operates with universal AC input range and offers 
full power up to 55°C. The output is adjustable from 12-15 volts, and can support up to 3000 microfarads of load capacitance. A green 
LED indicates output is present. The design is certified according to IEC/EN/UL 60950-1 Information Technology Equipment (ITE) and 
UL 508 Industrial Control Equipment (ICE). The series is  also fully compliant with RoHS Directive 2011/65/EU for environmental 
protection. NEC Class 2 and Limited Power Source (LPS) approvals are available for this product. 

 
 

Model Information 

Sync DIN Rail Power Supply 

 

Model  Number

 

Input  Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRS-12V50W1N

 

85-264Vac (120-375Vdc) 

12Vdc 

4A 

 

 

Model Numbering 

DR

 

S –

 

12V 

50W 

 

DIN Rail 

Product Series 

S – Sync Series 

Output Voltage 

50W series 

Single Phase  NEC Class 2 

Z – Without DC OK Relay  
      Contact 

R – With DC OK Relay  
      Contact 

 
 

 

*This picture is for reference to DRS-12V50W series only. 

Summary of Contents for DRS-24V30W-1AZ

Page 1: ...wer supply is designed for industrial applications requiring highly reliable power supply that must fit in a small space The Sync series operates with universal AC input range and offers full power up...

Page 2: ...Voltage 12Vdc Factory Set Point Tolerance 12Vdc 2 Output Voltage Adjustment Range 12 15Vdc Output Current 4A 48W max Output Power 48W Line Regulation 0 5 85 264Vac 100 load Load Regulation 1 0 85 264V...

Page 3: ...3 C Operating Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 000 Meters 6 560 ft Shock Test Non Operating IEC60068 2 27 Half Sine Wave 50G for a duration of 11ms 3 times per direction 9...

Page 4: ...ty Standards Directives Safety Entry Low Voltage SELV EN 60950 Electrical Safety TUV Bauart UL cUL recognized CB Scheme EN 60950 1 UL 60950 1 CSA C22 2 No 60950 1 File No E191395 IEC 60950 1 Limited P...

Page 5: ...2kV Surge IEC 61000 4 5 Level 3 Criteria A 1 Common Mode 3 2kV Differential Mode 4 1kV Conducted IEC 61000 4 6 Level 3 Criteria A1 150kHz 80MHz 10Vrms Power Frequency Magnetic Fields IEC 61000 4 8 Cri...

Page 6: ...IN Rail Power Supply 12V 50W 1 Phase NEC Class 2 DRS 12V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com March 2016 Rev 00 6 Block Diagram DR...

Page 7: ...March 2016 Rev 00 7 Device Description DRS 12V50W1NZ 1 Input terminal block connector 2 Output terminal block connector 3 DC voltage adjustment potentiometer 4 DC OK LED Green 5 Universal mounting sys...

Page 8: ...RS 12V50W1N All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com March 2016 Rev 00 8 Dimensions L x W x D 75 x 30 x 89 5 mm 2 95 x 1 18 x 3 52 inch DRS...

Page 9: ...til the surrounding air temperature is lowered or the load is reduced as far as necessary to keep the device in working condition and require removal re application of input AC voltage in order to res...

Page 10: ...sk of explosion severe damage To guarantee sufficient convection cooling keep a distance of 80mm 3 14 inch above and below the device as well as a lateral distance of 25mm 0 98 inch to other units Not...

Page 11: ...to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is the...

Page 12: ...output current will operate in Hiccup mode The power supply will return to normal operation after the short circuit is removed Overvoltage Protection Latch Mode The power supply s overvoltage circuit...

Page 13: ...n of the use of certain hazardous substances in electrical and electronic equipment This product conforms to this standard Fig 3 Parallel Operation Connection Diagram The power supply units PSUs can a...