background image

TECHNICAL DATASHEET

 

CliQ II DIN Rail Power Supply 

24V 480W 1 Phase / DRP024V480W1B

□ 

 

  

All parameters are specified at 25°C ambient and AC input unless otherwise indicated.

 

  www.DeltaPSU.com (November 2020, Rev. 07)  

1

 

Highlights & Features 

Universal AC input voltage range

Power will not de-rate for the entire input voltage range

High Efficiency > 90.0%

Power Boost of 150% for 5 seconds and 200% for 2 seconds

Full corrosion resistant aluminium casing

Extreme low temperature cold start at -40°C

Conformal coating on PCBA

s

 to protect against common 

dust

 

and chemical pollutants

Hazardous Locations approval to ATEX and Class I, Div 2

 

(DRP024V480W1BA)

Certified according to IEC/EN/UL 62368-1

Safety Standards 

CB Certified for worldwide use 

Model Number:

   

DRP024V480W1B

 

Unit Weight:

 

 

1.37 kg (3.02 lb) 

Dimensions (L x W x D):

  121 x 144 x 118.6 mm 

(4.76 x 5.67 x 4.67 inch) 

General Description 

The CliQ II DIN rail power supply series from one of the world’s leading power supply companies, Delta Electronics Group, offers 

output voltage of 24V. These products are encased in rugged yet lightweight full aluminium body that can withstand shock and vibration 

according to IEC 60068-2 standard. The  DRP024V480W1B

 can  operate over a wide temperature range of -25°C to +75°C. The 

series of single phase products also features universal AC input voltage range from 85Vac to 264Vac and the power will not de-rate 

throughout the entire range. Another great feature is the conformal coating on the PCBA which allows selected models to be certified to 

ATEX and Class I, Div 2 for use in hazardous locations. The design conforms to harmonic current emission IEC/EN 61000-3-2, Class A. 

Model Information 

CliQ II DIN Rail Power Supply 

Model  Number

 

Input Voltage Range

 

Rated Output  Voltage

 

Rated Output  Current

 

DRP024V480W1B

 

85-264Vac (120-375Vdc)

24Vdc 

20.0A 

Model Numbering 

DR

 

P

 

024V

 

480W

 

1

 

B

 

 

DIN Rail 

Power Supply 

Output Voltage  Output Power 

Single Phase 

CliQ II Series 

A - Metal Case, 

      with Class I, Div 2 
N - Metal Case, 

      without Class I, Div 2 

Summary of Contents for DRP024V480W1B Series

Page 1: ...pply series from one of the world s leading power supply companies Delta Electronics Group offers output voltage of 24V These products are encased in rugged yet lightweight full aluminium body that ca...

Page 2: ...e 24Vdc 2 Output Voltage Adjustment Range 24 28Vdc Output Current 20 0A continuously operating at 24V 30 0A Power Boost for 5 seconds at 24V refer to the details in the Functions section 40 0A Power B...

Page 3: ...g Humidity 5 to 95 RH Non Condensing Operating Altitude 0 to 2 500 Meters 8 200 ft Shock Test Non Operating IEC 60068 2 27 30G 300m S for a duration of 18ms 1 time per direction 2 times in total Vibra...

Page 4: ...L 62368 1 and CSA C22 2 No 62368 1 File No E191395 CB Scheme IEC 60950 1 IEC 62368 1 Industrial Control Equipment UL cUL listed UL 508 and CSA C22 2 No 107 1 01 File No E315355 CSA CSA C22 2 No 107 1...

Page 5: ...z 2GHz 3V M 80 modulation 1KHz 2GHz 2 7GHz 1V M 80 modulation 1KHz Electrical Fast Transient Burst IEC 61000 4 4 Level 3 Criteria A1 2kV Surge IEC 61000 4 5 Level 3 Criteria A1 Common Mode2 2kV Differ...

Page 6: ...DATASHEET CliQ II DIN Rail Power Supply 24V 480W 1 Phase DRP024V480W1B All parameters are specified at 25 C ambient and AC input unless otherwise indicated www DeltaPSU com November 2020 Rev 07 6 Bloc...

Page 7: ...nd AC input unless otherwise indicated www DeltaPSU com November 2020 Rev 07 7 Device Description 1 Input terminal block connector 2 Output terminal block connector 3 DC Voltage adjustment potentiomet...

Page 8: ...may run into Over Temperature Protection When activated the output voltage will go into bouncing mode and will recover when the surrounding air temperature is lowered or the load is reduced as far as...

Page 9: ...1 Tilt the unit upwards and insert it onto the DIN rail 2 Push downwards until stopped 3 Press against the bottom front side for locking 4 Shake the unit slightly to ensure that it is secured Fig 2 2...

Page 10: ...isk of burns Only plug in and unplug connectors when power is turned off DO NOT insert any objects into the unit Hazardous voltages may be present for up to 5 minutes after the input mains voltage is...

Page 11: ...0 to 90 of its final steady state set value Hold up Time Time between the collapse of the AC input voltage and the output falling to 95 of its steady state set value Inrush Current Inrush current is t...

Page 12: ...approved on 20A UL and 16A IEC branch circuits without additional protection device An external protection device is only required if the supplying branch has an ampacity greater than above Thus if a...

Page 13: ...it may cause damage to the PSU Short Circuit Protection Auto Recovery The power supply s output OLP OCP function also provides protection against short circuits When a short circuit is applied the out...

Page 14: ...tem load from Vout Please note that output voltage Vout from DRR module will be VO output voltage of power supply Vdrop in DRR module Vdrop will vary from 0 60V to 0 90V Typical 0 65V depending on the...

Page 15: ...arth wire or to the machine ground Fig 7 2 of 3 Phase System Input Operation Connection Diagram 2 of 3 Phase System Input Operation Delta s CliQ II can use on 2 of 3 phase system Please refer to the f...

Page 16: ...environment complying with EN 61000 3 2 is only necessary under special conditions Complying to this standard can have some technical drawbacks such as lower efficiency as well as some commercial asp...