MODEL: 

ITG100

INSTALLATION AND OPERATING INSTRUCTIONS 

CEILING / WALL VENTILATION FAN 
READ AND SAVE THESE INSTRUCTIONS 
 

General Safety Information 

1. 

Make sure that the electric service supply 
voltage is AC 120V, 60Hz. 

2. 

Follow all local electrical and safety codes, as 
well as the National Electrical Code (NEC) and 
the Occupational Safety and Healthy Act 
(OSHAct). 

3. 

Always disconnect the power source before 
working on or near the ventilating fan, motor or 
junction box. 

4. 

Protect the power cord from sharp edges, oil, 
grease, hot surfaces, chemicals or other 
objects. 

5. 

Do not kink the power cord. 

6. 

Do not install the unit where ducts are 
configured as shown in Fig. A. 

7. 

Provide suction parts with proper ventilation. 

8. 

This unit is UL listed for use over a bathtub or 
shower when installed in a GFCI protected 
branch circuit. 

 
WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO PERSONS, OBSERVE 
THE FOLLOWING: 

1. 

Use this unit only in the manner intended by the 
manufacturer. If you have any questions, 
contact the manufacturer. 

2. 

Before servicing or cleaning the unit, switch 
power off at service panel and lock the service 
disconnecting means to prevent power from 
being switched on accidentally. When the 
service disconnecting means cannot be locked, 
securely fasten a prominent warning device, 
such as a tag, to the service panel. 

3. 

Installation work and electrical wiring must be 
done by qualified person(s) in accordance with 
all applicable codes and standards, including 
fire-rated construction. 

4. 

Sufficient air is needed for proper combustion 
and exhausting of gases through the flue 
(chimney) of fuel burning equipment to prevent 
back drafting. Follow the heating equipment 
manufacturer’s guideline and safety standards 
such as those published by the National Fire 
Protection Association (NFPA), and the 
American Society for Heating, Refrigeration and 
Air Conditioning Engineers (ASHRAE), and the 
local code authorities. 

5. 

When cutting or drilling into wall or ceiling, do 
not damage electrical wiring and other hidden 
utilities. 

6. 

Ducted fans must always be vented to the 
outdoors. 

7. 

If this unit is to be installed over a tub or shower, 
it must be marked as appropriate for the 
application and be connected to a GFCI 
(Ground Fault Circuit Interrupter) – protected 
branch circuit. 

8. 

Do not use this unit with any other solid-state 
control device. Solid-state controls devices may 
cause harmonic distortion, which can cause a 
motor humming noise. 

9. 

NEVER place a switch where it can be reached 
from a tub or shower. 

10.  Not to be installed in a ceiling thermally 

insulated to a value greater than R50. (This is 
required for installation in Canada only). 

 

Turning angle too large

Duct shrink

Too many elbows

Elbow near the body

Body

Minimum 18 in.

 

CAUTION

 

1. 

For General Ventilating Use Only. Do Not Use 
To Exhaust Hazardous Or Explosive Materials 
And Vapors. 

2. 

Not for use in cooking area. (Fig. B) 

3. 

This product must properly connect to the 
grounding conductor of the supply circuit. 

4. 

To reduce the risk of injury to persons, install 
the fan at least 8.2 feet (2.5m) above the floor. 

Cooking area

 

SUPPLIED ACCESSORIES

 

Part name 

Appearance 

Quantity 

Grille 

 

Fan & 

Housing 

 

4” Duct 

 

Screw 

(M4x12) 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

INSTALLATIONS 

Proper insulation around the fan to minimize building   
heat loss and gain. 4” circular duct is recommended 
for installation. The ducting from this fan to the 
outside of building has a strong effect on the air flow, 
noise and energy use of the fan. Use the shortest, 
straightest duct routing possible for best performance, 
and avoid installing the fan with smaller ducts than 
recommended. Insulation around the ducts can 
reduce energy loss and inhibit mold growth. Fans 
installed with existing ducts may not achieve their 
rated air flow. 

 

 

 
Install with wood frame 

Model No. 

ITG100 

Install Dim. 

(Inch) 

7-1/2 x 7-1/4 

1. 

Remove motor plate from housing by 
removing three screws. (Fig. C) 

2. 

Remove wiring cover from housing by pulling 
straight out. Choose a hole and use a slotted 
screwdriver to remove it. (Fig. D) 

3. 

Follow all local electrical and safety codes. 
NEVER place a switch where it can be 
reached from a tub or shower. Connect wires 
as shown in wiring diagrams. (Fig. E) 

4. 

Using wire nuts(not provided), connect house 
power cable to ventilating fan wires. 14 AWG 
(2.1 mm

2

) is the smallest conductor that shall 

be used for branch-circuit wiring. (Fig. F) 

5. 

Insert the duct into the duct connector and 
tape all ductworks connection to make them 
secure and airtight. Install the duct with a 
gradient 1°~2° to the outside.  (Fig. G) 

6. 

New installation prior to finishing the 
ceiling or wall:
 Insert the fan between joists. 
Make sure the fan body is level and 
perpendicular with the joist. (Fig. H) 

7. 

Replacement installation: After making 
electrical and ductwork connections (see steps 
2~5), nail housing in place. Drive nails through 
the housing where indicated by arrows. (Fig. I) 

8. 

New installation in an existing ceiling or 
wall:

 

Bend tabs outward 90°(Use a screw 

driver if desired) and position housing so that 
tabs rest against bottom edge of joists (or front 
of stud). Nail housing to joist or stud using four 
nails to ensure a solid, quiet installation. 
Ceiling installations: Tabs on opposite side of 
housing can be bent outward to rest on top of 
1/2" ceiling material and provide extra stability. 
(Fig. J) 

9. 

Plug in the motor and locking the fan body 
back by using three screws. (Fig. C) 

10.  Squeeze grille springs together and insert 

springs into slots in motor plate. Push grille up 
against ceiling or wall. When the power on, 

Fig. A 

Fig. B 