VENTILATION FAN / LED LIGHT

MODELS 150F/150LEDNL/150LED-ADJ/150DS

Installation and Operating Instructions

1.   Make sure that the electric service supply voltage 

        

is AC 120V, 60Hz. 

2.   Follow all local electrical and safety codes, as well 

        

as the National Electrical Code (NEC) and the 

        

Occupational Safety and Health Act (OSH Act).

3. 

  

Always disconnect the power source before 

        

working on or near the ventilating fan, motor or 

        

junction box.

4.   Protect the power cord from sharp edges, oil, 

        

grease,

 

hot surfaces, chemicals or other objects.

5.   Do not kink the power cord.

6.   Do not install the unit where ducts are configured 

        

as shown in Fig.A.

7.   Provide suction parts with proper ventilation.

8.   This unit is UL Listed for use over a bathtub or 

        

shower when installed in a GFCI protected branch 

        

circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: 

1.   Use this unit only in the manner intended by the 

        

manufacturer. If you have questions, contact the 

        

manufacturer.

2.   Before servicing or cleaning the unit, switch the 

        

power off at the service panel and lock the service 

        

disconnecting means to prevent the power from 

        

being switched on accidentally. When the service 

        

disconnecting means cannot be locked, securely 

        

fasten a prominent warning device, such as a tag, 

        

to the service panel.

3.   Installation work and electrical wiring must be done 

        

by a qualified person(s) in accordance with all 

        

applicable codes and standards, including fire-rated 

        

construction.

4.   Sufficient air is needed for proper combustion and

        

exhausting of gases through the flue (chimney) of 

        

fuel burning equipment to prevent backdrafting. 

        

Follow the heating equipment manufacturer’s 

        

guideline and safety standards such as those 

        

published by the National Fire Protection 

        

Association (NFPA), and the American Society of 

        

Heating,  Refrigeration and Air-Conditioning 

        

Engineers (ASHRAE) and local code authorities.

5.   When cutting or drilling into the wall or ceiling, do 

        

not damage electrical wiring and other hidden 

        

utilities.

6.   Ducted ventilating fans must always be vented to 

        

the outdoors. 

7.   If this unit is to be installed over a tub or shower, it

        

must be marked as appropriate for the application 

        

and be connected to a GFCI (Ground Fault Circuit

        

lnterrupter) – protected branch circuit.

8.   Do not use this unit with any other solid-state 

        

control device. Solid-state control device may 

        

cause harmonic distortion, which can cause a 

        

motor humming noise.

        

(Avertissement: ne convient pas à des régulateurs 

        

de vitesse à semi-conducteurs).

9.   NEVER place a switch where it can be reached 

        

from a tub or shower.

10. Not to be installed in a ceiling thermally insulated to 

        

a value greater than R50. (This is required for 

     

        

installation in Canada only).

11. Do not open/disassemble LED light engine.

Fig. A

CAUTION

1. For general ventilating use only. Do Not Use To 

Exhaust Hazardous Or Explosive Materials And 

Vapors.

2. Not for use in cooking areas. (Fig.B)
3. This product must properly connect to the 

grounding conductor of the supply circuit.

4. To reduce the risk of injury to persons, install the 

fan at least 8.2 feet (2.5m) above the floor. 

Cooking area

Do not install above or

inside this area

Cooking

Equipment

Fig. B

45

°

45

°

Turning angle too large

Too many elbows

Duct shrink

Elbow near the body

.

Body

Minimum 18 in.

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION

READ AND SAVE THESE INSTRUCTIONS 

GENERAL SAFETY INFORMATION

PREPARATION

Tools Required for Assembly (not included): Hammer, 

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape,

Phillips Head Screwdriver, Utility Knife

Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box
before beginning installation.

   Carefully remove unit from carton.

Check area above installation location to be sure

that wiring can run to the planned location and

that duct work can be run. Make sure the area is

sufficient for proper ventilation.

Inspect duct work and wiring before proceeding

with installation.

Before installation, provide inspection and future

maintenance access at a location that will not

interfere with installation work.

You may need the help of a second person to

install this fan: one person on the attic side and

one on the room side.

Note: Installations may vary depending on how the

previous bath fan was installed. Supplies necessary

for the installation of your bath fan are not all included.

However, most are available at your local home

improvement or hardware store.

 

Proper insulation around the fan to minimize building

heat loss and gain. 6 in. circular duct is recommended

for installation. The ducting from this fan to the

outside of building has a strong effect on air flow,

noise and energy use of the fan. Use the shortest,

straightest duct routing possible for best performance,

and avoid installing the fan with smaller ducts than

recommended. Insulation around the ducts can reduce 

energy loss and inhibit mold growth. Fans installed with 

existing ducts may not achieve their rated air flow.

Roof cap

(with built-in

damper)

Seal gap

around 

housing

Caulk termination

to duct

Fan housing

Short piece of flexible

duct helps alignment

and absorbs sound

or

Wall cap

(with built-in

damper)

Wall cap

(with built-in

damper)

2~3 ft straight run 

before elbow

   The fan will operate most efficiently when located

where the shortest possible duct run and minimum

number of elbows will be needed.

Use a roof cap or wall cap that has a built-in

damper to reduce backdrafts.

External timer can be used in conjunction with single 

speed mode only, please contact Delta Breez 

customer service and consult with a licensed 

electrician for compatibility.

External dimmer can be used in conjunction with 

LED light model, please contact Delta Breez 

customer service and consult with a licensed 

electrician for compatibility.

PACKAGE CONTENTS

PART NAME

APPEARANCE

QTY

Fan Body

1

Grille

1

Grille

1

Hanger Bar

13”(318.5mm)

2

Hanger Bar

13”(318.5mm)

2

Duct Connector

1

150F / 150DS

150LEDNL / 150LED-ADJ

MFG MODELS: VFB150E6A1 / VFB150E6LED1 / VFB150E6LED1-A / VFB150E6D1

(6”)