
Chapter 8 Parameters
ASDA-A2R Series
8-276
Revision December, 2014
PM-47
Max. Current of Linear Motor
Address:
Applicable
motor type
:
LM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
100
Unit
:
0.01A
Range
:
0 ~ the rated current of servo drive
Data Size
:
16bit
Format
:
DEC
Settings
:
PM-48
Max. Speed of Linear Motor
Address:
Applicable
motor type
:
LM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
5000
Unit
:
3
10
m/s
Range
:
0~15999
Data Size
:
16bit
Format
:
DEC
Settings
:
PM-49
Force Constant of Linear Motor
Address:
Applicable
motor type
:
LM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
0
Unit
:
0.01N / A
Range
:
0~177362
Data Size
:
32bit