
Chapter 8 Parameters
ASDA-A2R Series
8-272
Revision December, 2014
PM-30
The Max. Current of PM Motor
Address:
Applicable
motor type
:
SPM, IPM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
0x0100
Unit
:
0.01A
Range
:
0 ~ the rated current of servo drive
Data Size
:
16bit
Format
:
DEC
Settings
:
PM-31
PM Motor Rated Speed
Address:
Applicable
motor type
:
SPM, IPM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
3000
Unit
:
rpm
Range
:
0 ~ 6000
Data Size
:
16bit
Format
:
DEC
Settings
:
PM-32
The Max. Speed of PM Motor
Address:
Applicable
motor type
:
SPM, IPM
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
5000
Unit
:
rpm
Range
:
0~6000
Data Size
:
16bit