Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-259
The filter setting of AB pulse from signal converter box:
0 = BYPASS
1 = 16M
2 = 8M
3 = 3M
Take pulse width 16Mhz(62.5ns) as the example,
When the width of single-phase pulse is smaller than 62.5ns,
the signal will be filtered.
The setting of signal source:
0 = comes from CN2
1 = comes from CN5
PM-04
Encoder Resolution
Address:
Applicable
motor type
:
ALL
Related Section: -
Operational
Interface
:
Panel / Software Communication
Default
:
2500
Unit
:
Permanet magnet synchronous rotary
motor:
rev
pulse
/
(square wave digital siganl)
rev
periods
/
(sinusoid analog signal)
Permanet magnet synchronous linear
motor:
pulse
m
/
10
5
(square wave digital
siganl)
period
m
/
10
3
(sinusoid analog
signal)
Range
:
64~
1
2
29
Data Size
:
32bit
Format
:
DEC
Settings
:
PM-05
The Interpolation of Signal Converter Box
Address:
Applicable
motor type
:
ALL
Related Section: -
Operational
Interface
:
Panel / Software Communication
62.5ns
62.5ns