Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-191
F033h (1~16777215).
Failure code
F034h
The protection level, P5-94 exceeds the
allowable range (0~7).
Success code
1003h
Command code
0004h
Motion parameter protection: unlock the
protection
Macro parameters
P5-96= enter the password (1~16777215)
This function can be executed when activating the function of
parameter protection.
If the protection function is unlocked, repeatly execute this function
will sent back the failure code.
If entering the wrong password, failure code Ennn will be sent back.
nnn means the rest decode number. It will be minused one number
after one failure. When the number is 0, it will be locked for good.
Failure code
F041h
Protection function is unlocked and it cannot
repeatly unlock.
Failure code
F043h
The password setting exceed the allowable
range (1~16777215)
Failure code
F044h
The number of times of entering wrong
password exceeds the limit: Lock for good.
Reset the parameter (P2-08=10) to unlock it is
the only method. However, all parameter will
return to the default value.
Failure code
Ennnh
Incorrect password setting: Failed to unlock.
nnn: the rest decode number. It will be minused
one number after one failure. When the number
is 0, it will be locked for good.
Success code
1004h