Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-181
Control
Mode
:
PR
Unit
:
-
Range
:
1 ~ 32767
Data Size
:
16bit
Format
:
DEC
Settings
:
When receiving pulse number P of the Master, E-Cam will rotate
M circle, which means the M cycle of the E-Cam table.
NOTE
This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
P5-84
ECMP E-CAM: Master Gear Ratio Setting P
Address: 05A8H
05A9H
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.11
Default
:
3600
Control
Mode
:
PR
Unit
:
-
Range
:
10 ~ 1073741823,
and P5-82 x P5-83
<=
P5-84
and P5-82 x P5-84
<=
2147483647
Data Size
:
32bit
Format
:
DEC
Settings
:
When receiving pulse number P of the Master, E-Cam will rotate
M circle, which means the M cycle of the E-Cam table.
NOTE
This parameter can be wrote when E-Cam stops (Please refer
toP5-88, X=0).
This parameter can be modified anytime, and has no limit that
mentioned above.
P5-85
ECME E-CAM: Number of Area
Address: 05AAH
05ABH
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.11
Default
:
0
Control
Mode
:
PR
Unit
:
-