Chapter 8 Parameters
ASDA-A2R Series
8-166
Revision December, 2014
bit 0: When the value of P5-58 is more than 0, set bit to 1 will
activate CMP. When comparing one data, the value of P5-58
will minus 1. When P5-58 is set to 0, the comparing is
completed and returns to 0. If P5-58 is 0, set bit 0 to 1 will
not do any comparing and return to 0 automatically. If bit 0
has already been set to 1, it is not allowed to write 1 as the
new value into the parameter. But it is ok to write 0 to disable
CMP.
bit 1: If this bit is 1, P5-58 will be reset after comparing the last
data. Then, start from the first data again. The cycle will
never end and bit 0 is always 1.
bit 2: If this bit is 1, CAP will be activated after comparing the last
data. (Set bit 0 of P5-39 to 1 and reset P5-38 to the previous
value) If CAP has already been activated, this function is
invalid.
bit 3: If this bit is 1, set the counter (P5-57) to 0 after comparing
the last data. For example, if the comparing data is set to
3000 (one data in total), the default value of the counter
(P5-57) is 0. It is expected to input 4000 pulse. When it
reaches the 3000
th
pulse, the CMP is completed and P5-57
returns to 0. When the pulse reaches 4000, P5-57=1000.
(No accumulative error)
P5-60
POV0 Target Speed Setting #0
Address: 0578H
0579H
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.10
Default
:
20.0 200
Control
Mode
:
PR
Unit
:
1 r/min
0.1 r/min
Range
:
0.1 ~ 6000.0
1 ~ 60000
Data Size
:
16bit
Format
:
DEC
Example
:
15 = 15 r/min
150 = 15 r/min
Settings
:
The 1
st
target speed of PR mode
P5-61
POV1 Target Speed Setting #1
Address: 057AH
057BH
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.10
Default
:
50.0 500