Chapter 8 Parameters
ASDA-A2R Series
8-154
Revision December, 2014
Format
:
DEC
Settings
:
The default value of this parameter is smaller (short deceleration
time) and it is used for deceleration time setting of auto protection.
P5-35
AC15
Acceleration/Deceleration Time (Number
#15)
Address: 0546H
0547H
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.10
Default
:
30
Control
Mode
:
PR
Unit
:
ms
Range
:
1 ~ 65500
Data Size
:
16bit
Format
:
DEC
Settings
:
The default value of this parameter is smaller (short deceleration
time) and it is used for short deceleration time and stops promptly
of auto protection.
P5-36
CAST CAPTURE - Start Address of Data Array
Address: 0548H
0549H
Operational
Interface
:
Panel / Software
Communication
Related Section:
7.11.1
Default
:
0
Control
Mode
:
ALL
Unit
:
-
Range
:
0 ~ (value set by P5-10 minus 1)
Data Size
:
16bit
Format
:
DEC
Settings
:
The first data CAPTURE obtained should be saved in the address
of data array.
NOTE
It is writable only when COMPARE stops (please refer to P5-39)