Chapter 8 Parameters
ASDA-A2R Series
8-142
Revision December, 2014
P5-06
HSPD2 2
nd
Speed Setting of Low Speed Homing
Address: 050CH
050DH
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
20.0 200
Control
Mode
:
ALL
Unit
:
Permanent magnet
synchronous rotary
motor: 1rpm
Permanent magnet
synchronous linear
motor:
6
10
m/s
Permanent magnet
synchronous rotary
motor: 0.1rpm
Permanent magnet
synchronous linear
motor:
6
10
m/s
Range
:
Permanent magnet
synchronous rotary
motor: 0.1 ~ 2000.0
Permanent magnet
synchronous linear
motor: 1~15999999
Permanent magnet
synchronous rotary
motor: 1 ~ 20000
Permanent magnet
synchronous linear
motor: 1~15999999
Data Size
:
32bit
Format
:
DEC
Example
:
Permanent magnet
synchronous rotary
motor: 1.5 = 1.5
r/min
Permanent magnet
synchronous linear
motor: 1500.0 =
0.015m/s
Permanent magnet
synchronous rotary
motor: 15 = 1.5 r/min
Permanent magnet
synchronous linear
motor: 15000 =
0.015m/s
Settings
:
The 2
nd
speed setting of low speed homing
P5-07
■
PRCM
Trigger Position Command (PR mode
only)
Address: 050EH
050FH
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
0
Control
Mode
:
PR
Unit
:
-
Range
:
0 ~ 1000
Data Size
:
16bit
Format
:
DEC