Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-109
P2-60
GR4 Gear Ratio (Numerator) (N2)
Address: 0278H
0279H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
128
Control
Mode
:
PT
Unit
:
pulse
Range
:
1 ~ (2
29
-1)
Data Size
:
32bit
Format
:
DEC
Settings
:
The numerator of electronic gear ratio can be selected via
DI.GNUM0 and DI.GNUM1 (Please refer to table 8.1). If
DI.GNUM0 and DI.GNUM1 are not set, P1-44 will automatically
be the numerator of electronic gear ratio. Please switch GNUM0
and GNUM1 in stop status to avoid the mechanical vibration.
P2-61
GR5 Gear Ratio (Numerator) (N3)
Address: 027AH
027BH
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
128
Control
Mode
:
PT
Unit
:
pulse
Range
:
1 ~ (2
29
-1)
Data Size
:
32bit
Format
:
DEC
Settings
:
Please refer to the description of P2-60.