Chapter 8 Parameters
ASDA-A2R Series
8-108
Revision December, 2014
P2-57
SBW The Bandwidth of Synchronous Control
Address: 0272H
0273H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
0
Control
Mode
:
ALL
Unit
:
Hz
Range
:
0~1023
Data Size
:
16bit
Format
:
DEC
Settings
:
If users do not know how to set P2-54~P2-56, setting the
bandwidth of synchronous control value will do since the value
will correspond to P2-54~P2-56. The bigger the bandwidth of
synchronous control value is, the better the synchronous effect
will be. When increasing the bandwidth of speed loop and
synchronous control, pay special attention to the response of
P2-25 which should be faster than the setting of the both
bandwidth.
P2-58
SVL
Low-pass Filter of Synchronous Speed
Error
Address: 0274H
0275H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
0
Control
Mode
:
ALL
Unit
:
0.1ms
Range
:
0~1000
Data Size
:
16bit
Format
:
DEC
Example
:
15 = 1.5 ms
Settings
:
If the synchronous control is influenced by low resolution and
causes noise (not a high-pitched but rough sound), low-pass filter
can be used to solve this problem. Please note that bandwith of
the synchronous control should be set as large as possible and
should larger than the bandwith of speed-loop.