Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-91
Format
:
DEC
Settings
:
The first setting value of resonance frequency. If P2-24 is set to 0,
this function is disabled. P2-43 and P2-44 are the second Notch
filter.
P2-24
DPH1
Resonance Suppression (Notch filter)
Attenuation Rate (1)
Address: 0230H
0231H
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.3.7
Default
:
0
Control
Mode
:
ALL
Unit
:
dB
Range
:
0 ~ 32 (0: disable the function of Notch
filter)
Data Size
:
16bit
Format
:
DEC
Settings
:
The first resonance suppression (notch filter) attenuation rate.
When this parameter is set to 0, the function of Notch filter is
disabled.
P2-25
NLP
Low-pass Filter of Resonance
Suppression
Address: 0232H
0233H
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.3.7
Default
:
0.2 (under 1kW) or
0.5 (other model)
2 (under 1kW) or
0.5 (other model)
Control
Mode
:
ALL
Unit
:
1 ms
0.1 ms
Range
:
0.0 ~ 100.0
0 ~ 1000
Data Size
:
16bit
Format
:
One decimal
DEC
Example
:
1.5 = 1.5 ms
15 = 1.5 ms
Settings
:
Set the low-pass filter of resonance suppression. When the value
is set to 0, the function of low-pass filter is disabled.