Chapter 8 Parameters
ASDA-A2R Series
8-90
Revision December, 2014
P2-21
DO4 DO4 Functional Planning
Address: 022AH
022BH
Operational
Interface
:
Panel / Software
Communication
Related Section:
Table 8.2
Default
:
105
Control
Mode
:
ALL
Unit
:
-
Range
:
0 ~ 0x013F (the last two codes are DO
code)
Data Size
:
16bit
Format
:
HEX
Settings
:
Please refer to the description of P2-18
P2-22
DO5 DO5 Functional Planning
Address: 022CH
022DH
Operational
Interface
:
Panel / Software
Communication
Related Section:
Table 8.2
Default
:
7
Control
Mode
:
ALL
Unit
:
-
Range
:
0 ~ 0x013F (the last two codes are DO
code)
Data Size
:
16bit
Format
:
HEX
Settings
:
Please refer to the description of P2-18
P2-23
NCF1 Resonance Suppression (Notch filter) (1)
Address: 022EH
022FH
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.3.7
Default
:
1000
Control
Mode
:
ALL
Unit
:
Hz
Range
:
50 ~ 1000
Data Size
:
16bit