Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-73
P1-57
CRSHA
Motor Crash Protection (torque
percentage)
Address: 0172H
0173H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
0
Control
Mode
:
ALL
Unit
:
%
Range
:
0 ~ 300
Data Size
:
16bit
Format
:
DEC
Settings
:
Setup protection level (for the percentage of rated torque, set the
value to 0 means to disable the function, set the value to 1 or
number above means to enable the function)
P1-58
CRSHT Motor Crash Protection Time
Address: 0174H
0175H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
1
Control
Mode
:
ALL
Unit
:
ms
Range
:
0 ~ 1000
Data Size
:
16bit
Format
:
DEC
Settings
:
Setup the protection time:
When it reaches the level, AL030 occurs after exceeding the
protection time.
NOTE
This function is only suitable for non-contactable application, such
as electric discharge machines. (please setup P1-37 correclty).
P1-59
MFLT Analog Speed Command
Address: 0176H
0177H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
0.0 0
Control
Mode
:
S