Chapter 8 Parameters
ASDA-A2R Series
8-72
Revision December, 2014
Settings
:
In position mode (PT), if the deviation pulse number is smaller
than the setting range (the setting value of parameter P1-54),
DO.TPOS is ON.
In position register (PR) mode, if the deviation between the target
position and the actual motor position is smaller than the setting
range (the setting value of parameter P1-54), DO.TPOS is ON.
P1-55
MSPD Maximum Speed Limit
Address: 016EH
016FH
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
Same as the rated speed of each model
Control
Mode
:
ALL
Unit
:
Permanent magnet synchronous rotary
motor: rpm
Permanent magnet synchronous linear
motor:
3
10
m/s
Range
:
0 ~ max.speed
Data Size
:
16bit
Format
:
DEC
Settings
:
The default of the max. speed of servo motor is set to the rated
speed.
P1-56
OVW Output Overload Warning Level
Address: 0170H
0171H
Operational
Interface
:
Panel / Software
Communication
Related Section: -
Default
:
120
Control
Mode
:
ALL
Unit
:
%
Range
:
0 ~ 120
Data Size
:
16bit
Format
:
DEC
Settings
:
The setting value is 0 ~ 100, if the servo motor continuously
outputs the load and is higher than the setting proportion (P1-56),
the early warning for overload (DO is set to 10, OLW) will occur.
If the setting value is over 100, it will disable this function.