Chapter 8 Parameters
ASDA-A2R Series
8-64
Revision December, 2014
Range
:
Permanent magnet synchronous rotary
motor: 0 ~ 5000
Permanent magnet synchronous linear
motor: 0 ~ 15999
Data Size
:
16bit
Format
:
DEC
Settings
:
Maximum Speed of Analog Speed Command:
In speed mode, the analog speed command inputs the swing
speed setting of the max. voltage (10V).
Permanent magnet synchronous rotary motor:
For example, if the setting is 3000, when the external voltage
input is 10V, it means the speed control command is 3000r/min. If
the external voltage input is 5V, then the speed control command
is 1500r/min.
Permanent magnet synchronous linear motor:
If the setting is 3000, when the external voltage input is 10V, it
means the speed control command is 3m/s. If the external voltage
input is 5V, then the speed control command is 1.5m/s.
Speed control command = input voltage value x setting value
/
10
In position or torque (force) mode, analog speed limit inputs the
swing speed limit setting of the max. voltage (10V).
Speed limit command = input voltage value x
setting value
/
10
P1-41
▲
TCM
Maximum Output of Analog Torque
(Force) Speed
Address: 0152H
0153H
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.4.4
Default
:
100
Control
Mode
:
ALL
Unit
:
%
Range
:
0 ~ 1000
Data Size
:
16bit
Format
:
DEC