Chapter 8 Parameters
ASDA-A2R Series
8-56
Revision December, 2014
Range
:
10 ~ 1000
Data Size
:
16bit
Format
:
DEC
Example
:
150= 15 Hz
Settings
:
The setting value of the first low-frequency vibration suppression.
If P1-26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression
Gain (1)
Address: 0134H
0135H
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.2.9
Default
:
0
Control
Mode
:
PT / PR
Unit
:
-
Range
:
0 ~ 9 (0: Disable the first low-frequency
filter)
Data Size
:
16bit
Format
:
DEC
Settings
:
The first low-frequency vibration suppression gain. The bigger
value it is, the better the position response will be. However, if the
value is set too big, the motor will not be able to smoothly operate.
It is suggested to set the value to 1.
P1-27
VSF2 Low-frequency Vibration Suppression (2)
Address: 0136H
0137H
Operational
Interface
:
Panel / Software
Communication
Related Section:
6.2.9
Default
:
1000
Control
Mode
:
PT / PR
Unit
:
0.1 Hz
Range
:
10 ~ 1000
Data Size
:
16bit
Format
:
DEC
Example
:
150 = 15 Hz
Settings
:
The setting value of the second low-frequency vibration
suppression. If P1-28 is set to 0, then it will disable the second
low-frequency filter.