Chapter 8 Parameters
ASDA-A2R Series
Revision December, 2014
8-41
Control Mode Settings
Mode
PT PR
S
T
Sz
Tz
Single Mode
00
▲
01
▲
02
▲
03
▲
04
▲
05
▲
Dual Mode
06
▲
▲
07
▲
▲
08
▲ ▲
09
▲
▲
25B
0A
▲ ▲
0B
CANopen Mode
0C Reserved
26B
0D
▲ ▲
Multiple Mode
0E
▲ ▲ ▲
0F
▲ ▲
▲
PT: Position Control Mode (The command source is external
pulse and analog voltage which can be selected via DI.
PTAS. Analog voltage can be used soon.)
PR: Position Control Mode (The command source is internal
signal which provides 64 positions and can be selected via
DI.POS0~POS5.It also provides various ways of Homing.)
S: Speed Control Mode (The command source is the external
analog voltage and register. It can be selected via DI. SPD0,
SPD1.)
T: Torque (force) Control Mode (The command source is the
external analog voltage and register. It can be selected via DI.
TCM0, TCM1.)
Sz: Zero Speed / Internal Speed Command
Tz: Zero Torque / Internal Torque Command
Dual Mode: It can switch mode via the external Digital Input
(DI). For example, if it is set to the dual mode of PT/S
(Control mode setting: 06), the mode can be switched via DI.
S-P (Please refer to table 7.1).
Multiple Mode: It can switch mode via the external Digital
Input (DI). For example, if it is set to multiple mode of
PT/PR/S (Control Mode Setting: 12), the mode can be
switched via DI. S-P, PT-PR (Please refer to table 7.1).