Chapter 4 Panel Display and Operation
ASDA-A2R Series
Revision December, 2014
4-5
4.3 Status
Display
4.3.1 Setting Saved Display
When finishing editing parameter, press the SET Key to save the setting. The panel will
display the setting status according to the setting for a second.
Displayed Symbol
Description
The setting value is saved correctly. (Saved)
Read-only parameter. Write-protected. (Read-Only)
Enter the wrong password or no password has been entered.
(Locked)
Incorrect setting value or enter the reserved setting value. (Out of
Range)
No entering is allowed when it is Servo ON. (Servo On)
Parameter will be effective after the servo drive is re-power on.
(Power On)
4.3.2 Decimal
Point
Displayed Symbol
Description
High byte / low byte indication: When the data is displayed in
decimal 32 bits, it is for indicating the current high or low byte.
Negative sign: When the data is displayed in decimal format, the two
decimal points in the left represents the negative sign, no matter it is
showed in 16 or 32 bits. When it is showed in hexadecimal format, it
only shows positive sign.
4.3.3 Alarm
Message
Displayed Symbol
Description
When there is an error of the drive, it will show ‘AL’ as the alarm
sign and ‘nnn’ as the alarm code.
For further explanation, please refer to Chapter 7, P0-01,
parameter description, or Chapter 11, Troubleshooting.
4.3.4 Positive and Negative Sign Setting
Displayed Symbol
Description
When entering into the Editing Setting Mode, pressing UP / DOWN
Key can increase or decrease the displayed content. The SHIFT
Key can change the desired adjusted carry value. (The carry value
is blinking at the moment.)
Pressing the SHIFT Key for two seconds can switch the positive (+)
and negative (-) sign. If the parameter is over the range after
switching the positive or negative sign, then it cannot be switched.