Delta Networking – Agema Family
AGC032 Spine Switch
agema.deltaww.com
Installation Guide
Page 1: ...Delta Networking Agema Family AGC032 Spine Switch agema deltaww com Installation Guide...
Page 2: ...able standard AS NZS CISPR 32 Class A ICES 003 EN55032 Class A VCCI Class A FCC CFR 47 Part 15 Subpart B Class A Safety Applicable standard EN 60950 1 Second Edition UL 60950 1 Second Edition CAN CSA...
Page 3: ...t limit par un cadenas un outil une cl ou par un autre moyen et est contr l par l autorit responsable des lieux L acc s n est permis que pour le personnel de service ou les utilisateurs qui ont t info...
Page 4: ...s installed in the restricted access location it should have a separate protective earthing terminal on the chassis which must be permanently connected to earth ground to adequately ground the chassis...
Page 5: ...acc s restreint l quipement doit tre dot d une borne de mise terre distincte sur le ch ssis qui doit tre branch e ad quatement et en permanence afin de le mettre terre et prot ger les utilisateurs con...
Page 6: ...Fan Tray Module 10 Chapter 3 Installation 11 3 1 Rack Mounting 11 3 2 Installing an Optional QSFP28 QSFP DD Transceiver 13 3 3 Installing an Optional SFP Transceiver 14 3 4 Connecting to the Console P...
Page 7: ...ale data center network with supports of advanced features such as MPLS VxLAN and NVGRE to meet the high demanding data center s requirement for virtualization features In addition to the rich bandwid...
Page 8: ...C version or 1600W DC version Hot swappable fan modules with 5 1 redundancy support Standard 1U chassis height System Fan Power status LED indication On board high performance CPU system with large me...
Page 9: ...SFP DD ports x 32 RJ 45 Console port x 1 SFP ports x 2 Figure 2 1 Front View 2 1 2 Rear View 6 Fan tray slots Redundant PSU x 2 Figure 2 2 Rear View NOTE The switch supports up to two PSU slots howeve...
Page 10: ...Module Fault Blinking Amber CPU Hang System over current or System over Voltage Off No Power Power 1 LED Solid Green Power supply 1 operating normally Solid Amber Power supply 1 failed Off Power is di...
Page 11: ...s port Link LED on the left side Solid Green A valid link at 10G is established on the port Solid Yellow A valid link at 1G is established on the port Off No link is established on the port Act LED on...
Page 12: ...ED Solid Green Input voltage is present and normal Off No input voltage DC Output LED Solid Green Output voltage is present and normal Off In a power limit or over current condition FAULT LED Solid Ye...
Page 13: ...100 1000Mbps auto sensing auto negotiation Spanning Tree Support Support IEEE802 1d STP Support IEEE802 1s MSTP Support IEEE802 1w RSTP L3 Hosts IPv4 UC up to 16K IPv6 UC up to 8K IPv4 MC up to 8K IPv...
Page 14: ...igure illustrates 400GbE switch in Super Spine for Data Center CLOS architecture Leaf Spine Leaf Spine Super Spine 400GbE Spine BGP BFD ECMP based Network POD 1 POD N 400GbE Spine AGC032 AGC032 AGC032...
Page 15: ...ront to back airflow direction Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Remove the power cable from the module prior to rem...
Page 16: ...he fan tray module is part of the switch air cooling system that provides cooling for the switch You must install the fan tray module in the switch that matches the airflow direction of the installed...
Page 17: ...1 Assemble the inner rail to switch Place the inner rail along one side of the switch align the mounting holes in the inner rail to the standoff of the switch and then fasten the inner rail to the sw...
Page 18: ...ch all the way to the rear of the rack Use one M5 rack mounting screw to fasten the front bracket to the rack cabinet Then repeat the similar step to assemble another front bracket Figure 3 3 Mounting...
Page 19: ...these steps 1 Consider network and cabling requirements to select an appropriate QSFP28 QSFP DD transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connec...
Page 20: ...iate SFP transceiver type 2 Insert the transceiver with the optical connector facing outward and the slot connector facing down Note that SFP transceivers are keyed so they can only be installed in on...
Page 21: ...to a Power Source 3 5 1 Installing an AC Power Supply To connect a switch to a power source 1 Insert the power cable plug directly into the AC socket of a PSU located at the back of the switch Power...
Page 22: ...tended to be supplied by UL Listed DC power source with rated 48V 60Vdc 20A minimum Tma 40 degree C and the altitude of operation 5000 m and the power cable should be 14AWG CAUTION Reversing polarity...
Page 23: ...ter for 10BASE T connections 4 1 1 Cabling Guidelines The RJ 45 port on the switch supports an automatic MDI MDI X pinout configuration so you can use a standard straight through twisted pair cable to...
Page 24: ...emperature that is not less than the recommended maximum operational temperature of the product You must also use an approved QSFP DD transceiver AVERTISSEMENT Pour des raisons de s curit lors de la s...
Page 25: ...ation of your network Cable type Unshielded twisted pair UTP or shielded twisted pair STP cables with RJ 45 connectors Category 3 or better for 10BASE T Category 5 or better for 100BASE TX and Categor...
Page 26: ...console port IEEE 802 3ab 1000BASE T on console port IEEE 802 3x Flow Control IEEE 802 3z 1000BASE X IEEE 802 3ae 10Gb s Ethernet IEEE 802 3ba 40GE s Ethernet IEEE 802 3by 25GE s and 50GE s Ethernet I...
Page 27: ...Technical Specifications Appendix 1 Item Description Environmental Specifications Operating Temperature 0 to 40 C Storage Temperature 20 to 70 C Operating Humidity 10 to 90 RH Storage Humidity 5 to 95...
Page 28: ...us manufacturers to perform repairs and or to build replacement products All replaced or repaired products will be warranted for the remainder of the original warranty period or thirty 30 days whichev...
Page 29: ...efective product return you shall be responsible for proper packaging and Delta will not take responsibility for any shipping damage due to your improper product packaging Disclaimer EXCEPT FOR THE WA...