background image

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire

extension cord which has a 3-prong grounding type plug and matching receptacle which will accept the machine’s
plug. When using an extension cord, be sure to use one heavy enough to carry the current of the machine. An
undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct
gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number,
the heavier the cord.

EXTENSION CORDS

FOREWORD

Delta Model 37-195 is a 6" Professional Jointer with a cutting capacity of 6-1/8" (156mm) width, 1/8" depth (3mm max.)
and 1/2" (13mm) rabbeting. Unit includes; heavy-duty 1 hp, 120/240 volt induction motor, stand, dust chute, fence, three-
knife cutterhead, cutterhead guard, and push blocks. 

Carefully unpack the machine and all loose items from the shipping container(s). Remove the protective coating from
all unpainted surfaces. This coating may be removed with a soft cloth moistened with kerosene (do not use acetone,
gasoline or lacquer thinner for this purpose). After cleaning, cover the unpainted surfaces with a good quality household
floor paste wax.

NOTICE: THE MANUAL COVER PHOTO ILLUSTRATES THE CURRENT

PRODUCTION MODEL.  ALL OTHER ILLUSTRATIONS ARE REPRESENTATIVE

ONLY AND MAY NOT DEPICT THE ACTUAL COLOR, LABELING OR

ACCESSORIES AND MAY BE INTENDED TO ILLUSTRATE TECHNIQUE ONLY.

5

Fig. D

Fig. D

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

120

up to 25

18 AWG

0-6

120

25-50

16 AWG

0-6

120

50-100

16 AWG

0-6

120

100-150

14 AWG

6-10

120

up to 25

18 AWG

6-10

120

25-50

16 AWG

6-10

120

50-100

14 AWG

6-10

120

100-150

12 AWG      

10-12

120

up to 25

16 AWG

10-12

120

25-50

16 AWG

10-12

120

50-100

14 AWG

10-12

120

100-150

12 AWG

12-16

120

up to 25

14 AWG

12-16

120

25-50

12 AWG

12-16

120

GREATER THAN 50 FEET NOT RECOMMENDED

MINIMUM GAUGE EXTENSION CORD

RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES

Ampere

Total Length

Gauge of

Rating

Volts

of Cord in Feet

Extension Cord

0-6

240

up to 50

18 AWG

0-6

240

50-100

16 AWG

0-6

240

100-200

16 AWG

0-6

240

200-300

14 AWG

6-10

240

up to 50

18 AWG

6-10

240

50-100

16 AWG

6-10

240

100-200

14 AWG

6-10

240

200-300

12 AWG      

10-12

240

up to 50

16 AWG

10-12

240

50-100

16 AWG

10-12

240

100-200

14 AWG

10-12

240

200-300

12 AWG

12-16

240

up to 50

14 AWG

12-16

240

50-100

12 AWG

12-16

240

GREATER THAN 100 FEET NOT RECOMMENDED

Fig. C

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

GROUNDING BLADE
IS LONGEST OF THE 3 BLADES

the plug. No adapter is available or should be used with
this machine.  If the machine must be re-connected for
use on a different type of electric circuit, the re-
connection should be made by qualified service
personnel; and after re-connection, the machine should
comply with all local codes and ordinances.

I N A L L C A S E S , M A K E C E R TA I N

THE RECEPTACLE IN QUESTION IS PROPERLY
G R O U N D E D . I F Y O U A R E N O T S U R E H AV E A
Q U A L I F I E D E L E C T R I C I A N C H E C K T H E
RECEPTACLE.

OPERATING INSTRUCTIONS

UNPACKING AND CLEANING

Summary of Contents for 37-195

Page 1: ...Model 37 275X PART NO 909995 01 22 03 Copyright 2003 Delta Machinery To learn more about DELTA MACHINERY visit our website at www deltamachinery com For Parts Service Warranty or other Assistance ple...

Page 2: ...will do the job better and be safer at the rate for which it was designed 10 USE RIGHT TOOL Don t force tool or attachment to do a job for which it was not designed 11 WEAR PROPER APPAREL No loose cl...

Page 3: ...jointer with the workpiece contacting the cutterhead 9 ALWAYS hold the workpiece firmly against the tables and fence 10 NEVER perform any operation Free hand which means using your hands to support o...

Page 4: ...must be connected to a permanent ground such as a properly grounded outlet box Whenever the adapter is used it must be held in place with a metal screw NOTE In Canada the use of a temporary adapter is...

Page 5: ...ION CORD RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES Ampere Total Length Gauge of Rating Volts of Cord in Feet Extension Cord 0 6 120 up to 25 18 AWG 0 6 120 25 50 16 AWG 0 6 120 50 10...

Page 6: ...Mounting Bracket 4 Switch Mounting Bracket 5 Cutterhead Guard 6 Fence Tilting Handles 2 7 Fence 8 Push Blocks 2 9 12 14mm Open End Wrench 10 8 10mm Open End Wrench 11 8mm Hex Wrench 12 6mm Hex Wrench...

Page 7: ...Flat Washer 3 28 11 32 Flat Washer 1 29 M8 Flat Washer 10 30 M10 2 Lockwasher 3 31 M8 1 Lockwasher 10 32 5 16 Lockwasher 1 33 M8x1 25 Hex Nut 2 34 5 16 18 Hex Nut 1 35 Key ASSEMBLY FOR YOUR OWN SAFET...

Page 8: ...e a M10 2 lockwasher I on a M10x1 5x20mm hex socket head screw H and a M10 flat washer onto the screw Insert the screw through the hole in the stand and thread the screw into the tapped hole in the bo...

Page 9: ...finger pressure 2 If an adjustment is required the motor can be raised or lowered to obtain the correct belt tension 3 Tighten motor mounting hardware after tension is applied making sure alignment of...

Page 10: ...and the cutterhead pulley guard carriage mounting bracket 2 Fig 16 illustrates fence carriage assembly properly mounted Fig 15 D A C B Fig 16 ASSEMBLING FENCE 1 Fasten fence A Fig 17 to fence carriage...

Page 11: ...OUNTING BRACKET 1 Align the two holes in the switch mounting bracket A Fig 22 with the two holes D in the back of the infeed table B Place an M8 flat washer E Fig 22 on an M8x1 25x30mm hex socket head...

Page 12: ...our 10 16x1 2 sheet metal screws D as shown A standard 4 dust collection hose can be attached to dust collector connector Fig 25 Fig 26 A C D B OPERATING CONTROLS AND ADJUSTMENTS STARTING AND STOPPING...

Page 13: ...and squeeze locking lever C and raise or lower handle B 3 NOTE When raising or lowering the infeed table a depth stop D Figs 35 and 36 will automatically stop the table at an 1 8 depth of cut To move...

Page 14: ...orm accurate jointing operations the outfeed table must be exactly level with the knives at their highest point of revolution This means that the knives must be parallel to the outfeed table and proje...

Page 15: ...wood after screws F have been turned Tighten four screws D Fig 41 by turning them counterclockwise after adjustment is made 6 Repeat these procedures for adjusting the remaining two knives if necessar...

Page 16: ...ver H Fig 46 IMPORTANT Do not leave the adjusting screws too loose It should take a little bit of effort to move the tables up or down Fig 46 F C F C A Fig 47 D G E D G B FENCE OPERATION The fence can...

Page 17: ...rn adjustment screw A until you are certain the fence is 90 degrees to the table Then tighten lock handle B and lock nut D 4 Loosen lock handle B Fig 52 and rotate flip stop G Then tilt fence out as f...

Page 18: ...oroughly clean and free of gum and pitch 7 Replace the knife locking bars D Fig 55 and knives C into each slot in the cutterhead C A R E M U S T B E TA K E N W H E N INSERTING THE KNIVES AS THE CUTTIN...

Page 19: ...KEEP HANDS AWAY FROM CUTTERHEAD ALWAYS USE PUSH BLOCKS WHENEVER POSSIBLE NEVER MAKE JOINTING AND PLANING CUTS DEEPER THAN 1 8 IN ONE PASS PLACEMENT OF HANDS DURING FEEDING At the start of the cut the...

Page 20: ...e to the right TAPER CUTS One of the most useful jointer operations is cutting an edge to a taper This method can be used on a wide variety of work Tapered legs of furniture are a common example Inste...

Page 21: ...the three knives Fig 70 MAINTENANCE AND REPAIRS SURFACING WARPED PIECES If the wood to be surfaced is dished or warped take light cuts until the surface is flat Avoid forcing such material down agains...

Page 22: ...FF HERE TO PUSH 1 4 WOOD CUT OFF HERE TO PUSH 1 2 WOOD NOTCH TO HELP PREVENT HAND FROM SLIPPING 1 2 SQUARES CONSTRUCTING A PUSH STICK Narrow pieces of stock that are close to 10 inch minimum length sh...

Page 23: ...s This warranty is Delta s sole warranty and sets forth the customer s exclusive remedy with respect to defective products all other warranties express or implied whether of merchantability fitness fo...

Page 24: ...Southern Avenue Suite 105 Phone 602 437 1200 Fax 602 437 2200 CALIFORNIA Ontario 91761 Los Angeles 3949A East Guasti Road Phone 909 390 5555 Fax 909 390 5554 San Leandro 94577 Oakland 3039 Teagarden...

Reviews: