background image

 

SIM Card replacement 

 29 

DLC-BX1-SP System Wiring with GP1 Logger 

Figure 21

  Wiring scheme with a GP1 logger using the cable 

harness used in Modem Box  

3G-DLC-BX1/SP. 

See alo Fig. 22 

Battery

Power

Power

To aerial

Solar 
Panel

Modem

Fuse

Modem

Regulator/charger

Text message trigger (optional)

To trigger text message 
connect the signal wire 
to earth

Modem

Modem

5-way M8

serial

se

ri

al

Po

w

er

 a

nd

 

oti

on

al

 tex

m

es

sa

ge 

tr

ig

ger

Summary of Contents for FX30

Page 1: ...User Manual for Modem Gateway for DeltaLINK Cloud Delta T Devices Ltd DLC UM 1 2 ...

Page 2: ...ct Description Standards Modem FX30 Refer to Sierra Wireless FX30 Hardware User Guide Solar regulator Steca Solsum6 6F 2004 108 EC EMC 2006 95 EC Low voltage directive Solar panel BP SX series IEC 61215 If the equipment is used with any non Delta T products it is the responsibility of the user to ensure the EMC compliance of any such measuring systems Design changes Delta T Devices Ltd reserves th...

Page 3: ...equirements 10 Modem Parts 11 Parts and wiring used with GP2 Loggers 12 Parts and wiring used with GP1 and DL6 loggers 14 1 Ensure the modem is powered 15 2 Set up DeltaLINK Cloud 18 Wiring 26 Modem Cable Harness for GP2 logger 26 GP2 Network cabling Options with Modem 26 System Wiring for GP2 Logger with modem gateway in M ENCL B2 metal enclosure 27 BX1 Modem Box Wiring Harnesses 28 DLC BX1 SP Sy...

Page 4: ...4 Contents SIM Card replacement 29 Warranty and Service 31 Terms and Conditions of Sale 31 Service Repairs and Spares 32 Technical Support 32 ...

Page 5: ...DLC BX1 SP polymer Modem Box with DeltaLINK Cloud enabled modem plus solar power battery The GP1 GP2 or DL6 logger s are mounted outside the box Other Documents You may also need to refer to the following GP2 User Manual GP1 Quick Start Guide DL6 Quick Start Guide Network Cabling for GP1 and DL6 Deltalink 3 8 or later on line Help Steca Solsum 6 6F Operating Manual Solar Panel Manufacturer s Instr...

Page 6: ...ta monitoring Share data and collaborate Automatic upload Mobile tablet and PC compatible Flexible charting and reporting SIM card provided Secure and encrypted DeltaLINK Cloud is a secure cloud connectivity data management and automatic data retrieval solution The website lets you monitor the status of your loggers and modem gateways graph and export the uploaded data and share access to data rep...

Page 7: ...ta T Gateway upload schedules can be customised from DeltaLINK Cloud The SIM cards provided by Delta T enable us to provide an optimum user experience and support service These Smart SIM cards can connect to multiple network providers which improves the chance of you having a stable connection Logger status can be monitored and program setting changed remotely Data generated by the loggers can be ...

Page 8: ...ch loggers are attached Then it is ready to use The modem power comes from an LBAT 4 battery shown in the bottom of both boxes The wiring arrangements of the two systems shown above are slightly different This is covered in later sections of this manual MD 3G DLC DeltaLINK Cloud enabled 3G modem installed with A GP2 logger controller in an M ENCL B2 metal enclosure A SOL 4 solar power charger regu...

Page 9: ... stage of their charge or discharge cycle must not be mounted in the enclosure without sufficient additional ventilation Do not use non approved batteries or other battery charger regulators in un ventilated enclosures For optimum thermal protection the Solsum solar charger regulator should be installed in the same housing as any external battery See also Warnings in the M ENCL B User Manual ...

Page 10: ...with DeltaLINK Cloud enabled modem and battery or 3G DLC BX1 SP polymer Modem Box with DeltaLINK Cloud enabled modem plus solar power battery A source of power is required for the modem such as the LBAT4 and SOL4 solar power system At 12V the modem s maximum consumption is up to 600mA when connecting and 212mA when communicating with the DeltaLINK Cloud servers and 74mA maximum otherwise The typic...

Page 11: ...n Microfit connector for power supply and optional alarm signal from logger USB 2 0 Micro B port to connect to PC Its use may be requested by Delta T Technical Support if diagnosing faults DB9 connector for serial data Power LED see page 17 Cellar antenna connector DO NOT PRESS SIM card slot ...

Page 12: ...B2 enclosure with modem cabling aerial SOL4 solar power regulator and LBAT4 battery Wiring scheme see also page 26 Power Power Power Aerial Enable text message Solar Panel RS232 Power Fuse Power Text message alarm Regulator charger To trigger text message connect the signal wire via a relay to earth Modem Modem Battery Fuse 6 3A 20mm ...

Page 13: ...e The cable harness is different for GP1 and DL6 loggers using the DLC Modem Box see page 28 Serial data via RS232 DB9 socket to modem Power and optional text message trigger to modem socket to modem Optional text message trigger from logger Fuse slow break 3A 25V 5x20mm Power and serial data from logger Ferrite bead ...

Page 14: ...ions with and without solar power Left DLC BX1 B with battery Right DLC BX SP solar power option with solar power regulator charger solar panel not shown and battery These DeltaLINK Cloud Modem Box systems are used with one or more externally connected GP1 or DL6 loggers via a GP1 network cable See also BX1 Modem Box Wiring Harnesses on pages 28 29 ...

Page 15: ... M12 serial cable connector This GP2 itself is receiving power from an external battery via a solar power regulator WARNING Cover the solar panel when wiring up the system as it will be live Power may also be supplied directly to the GP2 serial cable as shown in the GP2 network cabling diagram on page 26 Power Power Power Aerial Enable text message Solar Panel RS232 Power Fuse Power Text message a...

Page 16: ...that the battery power is also accessible to any GP1 logger externally connected on the GP1 cabling network If you don t want this to happen the wiring at the DIN rail can easily be altered see cable harness wiring scheme on page 28 WARNING Cover the solar panel when wiring up the system as it will be live Figure 7 Cabling scheme in the Modem Gateway Box type 3G DLC BX1 SP for use with GP1 or DL6 ...

Page 17: ...LED Modem Power LED Behaviour LED state Flash rate Meaning Off No power or input voltage 32 VDC or 4 75 VDC Solid Red Modem powered but not attached to cellular network Solid Amber Modem powered and attached to cellular network Note we do not use the User LED Figure 5 LED behaviour ...

Page 18: ... with a data package2 Connected logger to modem Powered up logger and modem Checked modem lights are flashing correctly You also need an internet connection This can be a smart phone a tablet or PC If using a PC it needs to be running a recent internet browser such as Internet Explorer version 9 or above You also need an email address 2 The data package is an allowance to transmit a certain number...

Page 19: ...to DeltaLINK Cloud and Create an Account Go to www deltalink cloud com and register as a DeltaLINK Cloud user with your email address and password If you have not yet registered click on Create an account to display the Registration page Figure 8 DeltaLINK Cloud ...

Page 20: ...20 Install Modem Gateway with a GP1 DL6 or GP2 logger Figure 9 The registration form for DeltaLINK Cloud ...

Page 21: ... logger 21 Once registered the DeltaLINK Cloud Welcome page should appear Figure 10 Welcome page The actual layout will change depending on the size of your screen 2 2 Add Gateway 2 2 1 Click on Manage Devices Figure 11 Manage Devices page Help ...

Page 22: ...d Gateway Type Select from the list 2G Modem Gateway FXT009 or 3G Modem Gateway FX30 Serial Number Enter the serial number written on the side of the DeltaLINK Cloud modem see below Access Code Enter the Access Code written on the side of the DeltaLINK Cloud modem see below Figure 12 The Add Gateway form and the location of serial number and access code for the DeltaLINK Cloud 2G or 3G modem SN AB...

Page 23: ...Install Modem Gateway with a GP1 DL6 or GP2 logger 23 Figure 13 Waiting for a new gateway to open 2 3 Add a Logger to the new Gateway 2 3 1 Click on Add Logger Figure 14 The Add Logger form ...

Page 24: ...tion Tell us a bit about your logger This information will appear in the Managed Devices list in DetaLINK Cloud Logger type Select one from the list provided This information is needed so that the DeltaLINK Cloud server knows how to interact with the logger correctly Serial Number This is required for DeltaLINK Cloud to connect to the logger e g GP1 01 024 This information is written on the logger...

Page 25: ...e status information as shown below Your logger is now added to DeltaLINK Cloud and will automatically update once a day The schedule can be changed by going to the gateway Settings Status page For further assistance log in at www deltalink cloud com to see DeltaLINK Cloud online Help See also https www delta t co uk deltalink cloud contact Delta T see page 32 Figure 15 Showing the Gateway and Log...

Page 26: ...from GP2 Ferrite bead Brown Blue Red Black Optional alarm signal from GP2 1 5 3 2 3 Grey Black White Blue 2 1 2 3 6 5 4 Fuse slow break 3A 250V 5x20mm MD 3G DLC Yellow GP2 USB GP2 RS232 GP2 NPT GP1 cabling network e g GP1 EXT xx where xx 1 5 10 or 25m GP2 GP1 M8 PC UK PC EU PC US PC IN PC CN GP2 PSU GP2 NPC MD 3G DLC modem antenna and cabling for use in M ENCL B2 enclosure along with GP2 and 12V b...

Page 27: ...Figure 18 3G Modem Gateway wiring with a GP2 logger Power Power Power Aerial Enable text message optional Solar Panel RS232 Power Fuse RS232 serial data Regulator charger To trigger text message connect the signal wire via a relay to earth Modem Modem Battery Fuse 6 3A 20mm Power 3G Modem ...

Page 28: ...RX TX Ferrite bead Fuse 3A 250V 5x20mm Slow break 2 4 1 5 3 To GP2 GP1 and or DL6 logger s To battery Optional alarm signal from logger DIN rail Fuse 3 15 A 20mm Brown Blue Black Red Blue Brown Blue Grey White Brown 1 5 3 2 2 1 2 3 6 5 4 3G DLC BX1 B Yellow 2 3 9 way D Connector To modem 5 way M8 connector on outside of Modem Box RX TX Ferrite bead Fuse 3A 250V 5x20mm Slow break 2 4 1 5 3 To GP1 G...

Page 29: ...using the cable harness used in Modem Box 3G DLC BX1 SP See alo Fig 22 Battery Power Power To aerial Solar Panel Modem Fuse Modem Regulator charger Text message trigger optional To trigger text message connect the signal wire to earth Modem Modem 5 way M8 serial serial Power and otional text message trigger ...

Page 30: ...pport To remove the SIM card 1 Use a Phillips screwdriver to remove the cover 2 Press in the SIM card and release it 3 Gently grip the SIM card and pull it out Te reinstall 1 Orient the SIM card as shown with the gold contacts on the SIM card facing up 2 Gently slide the SIM card into the slot until it clicks into place 3 Replace the cover Figure 22 Sim card installation ...

Page 31: ...pairing the goods free of charge at Delta T s premises in the UK during the warranty period If Delta T requires that goods under warranty be returned to them from overseas for repair Delta T shall not be liable for the cost of carriage or for customs clearance in respect of such goods However Delta T requires that such returns are discussed with them in advance and may at their discretion waive th...

Page 32: ...mally expect to complete repairs within one or two weeks of receiving the equipment However if the equipment has to be forwarded to our original supplier for specialist repairs or recalibration additional delays of a few weeks may be expected For contact details see below Technical Support Users in countries that have a Delta T distributor or technical representative should contact them in the fir...