10
Adjustment of Dispensing Mechanism
1. Adjust the dispensing mechanism toward the left to be at a minimum clearance with the base
plate, and ensure that the front end of the dispensing mechanism is parallel with the front end of
the base plate.
2. Unfasten the fixation screws on the horizontal conveying device board (opening).
3. Align the horizontal conveying plate opening with the track center, and ensure the sliding track
slides to the leftmost end at this time; then, fasten the screws unfastened in
Step 2
.
Parallel