LPPYRHE16
- 9 -
V2.3
4.2
LPPYRHE16AC
CONNECTIONS
The pyrheliometer LPPYRHE16AC has 4…20 mA output and requires 10…30 Vdc ex-
ternal power supply. It is to be connected to a power supply and an instrument with
4…20 mA input as shown in fig. 4.2. The load resistance of the instrument reading the
signal must be
≤
500
Ω
.
Connector
Function
Color
1
Positive (Iin)
Red
2
Negative (Iout)
Blue
3
Housing (C)
White
4
Cable shield (SH)
Black
Fig. 4.2: LPPYRHE16AC connections
4.3
LPPYRHE16AV
CONNECTIONS
The pyrheliometer LPPYRHE16AV has 0…1 V, 0…5 V or 0…10 V output (depending
on the ordered output) and requires external power supply: 10…30 Vdc for 0…1 V
and 0…5 V outputs, 15…30 Vdc for 0…10 V output. It is to be connected to a power
supply and an instrument with voltage input as shown in fig. 4.3. The load resistance
of the instrument reading the signal must be
≥
100 k
Ω
.
Connector
Function
Color
1
Output positive (+Vout)
Red
2
Output negative
Power supply negative (GND)
Blue
3
Power supply positive (+Vdc)
White
4
Cable shield (SH)
Black
Fig. 4.3: LPPYRHE16AV connections
CPM12AA4… cable
Sensor M12
male connector
Power supply
Connect to ground only if it is not possible to
ground locally the housing of the pyrheliometer
Instrument with
4…20 mA input
CPM12AA4… cable
Sensor M12
male connector
Power supply
Instrument
with
voltage input