background image

 
 

 
 
 
 
 
 

 
 
 
 
 

 
 
 

The quality level of our instruments is the result of the constant development of the 

product. This may produce some differences between the information written in this 
manual and the instrument you have purchased. We cannot completely exclude the 

possibility of errors in the manual, for which we apologize.  
The data, images and descriptions included in this manual cannot be legally asserted. 
We reserve the right to make changes and corrections with no prior notice.  

HD50R-MB 

Ethernet Data Logger 

ENGLISH 

REV. 1.0 

20/07/2018

 

Summary of Contents for HD50R-MB

Page 1: ...in this manual and the instrument you have purchased We cannot completely exclude the possibility of errors in the manual for which we apologize The data images and descriptions included in this manua...

Page 2: ...D50 2 V1 0 TABLE OF CONTENTS 1 INTRODUCTION 3 2 DESCRIPTION 4 3 CONNECTIONS 5 4 SOFTWARE 8 5 MODBUS 9 6 TECHNICAL CHARACTERISTICS 14 7 INSTRUMENT STORAGE 15 8 SAFETY INSTRUCTIONS 15 9 ORDERING CODES 1...

Page 3: ...up to 10 TCP IP Client simultaneously If the local network is connected to Internet the data can be regularly sent to an FTP address to the Cloud and via e mail For each detected quantity two alarm th...

Page 4: ...n gauge 3 Red POWER LED indicates the presence of the external power supply 4 Power supply input 5 RS485 line termination 6 Input for RS485 Modbus RTU sensors 7 RJ45 connector for Ethernet connection...

Page 5: ...the termination placing the short jumper next to the RS485 connector between the RT and CLOSE indications Otherwise remove the termina tion placing the short jumper between the RT and OPEN indication...

Page 6: ...ia a standard Ethernet cable The data logger is preset to get a dynamic IP address from the network DHCP server The IP address can be displayed and changed by connecting the data logger to a PC via US...

Page 7: ...D35AP S software It is possible to restore the factory parameters by placing the short jumper next to the NET RST push button between the 2 and 3 indications and then pressing the NET RST push button...

Page 8: ...FR21 SOFTWARE OPTION The HD35AP CFR21 option allows in addition to the features of the basic software both HD35AP S and HDServer1 the protection of recorded data and instrument con figuration in respo...

Page 9: ...units of measurement Index Unit of meas Index Unit of meas Index Unit of meas Index Unit of meas Index Unit of meas 0 C 13 inchHg 26 J m2 39 inch 52 l min 1 F 14 inchH2O 27 J cm2 40 counts 53 gallon...

Page 10: ...hold alarm 10 SW ABSOLUTE HUMIDITY in g m3 x10 11 B Absolute humidity alarm 0 OFF 1 lower threshold alarm 2 higher threshold alarm 12 SW WET BULB TEMPERATURE in the set measurement unit x10 13 B Wet b...

Page 11: ...ND SPEED measurement unit see TAB 12 1 5053 SW WIND SPEED resolution 2 100 1 10 0 1 1 0 1 2 0 01 General information 10000 W Year of last measurement 10001 W Month of last measurement 10002 W Day of l...

Page 12: ...EED ultrasonic anemometer lower alarm threshold in m s x100 93 SW Wind speed ultrasonic anemometer higher alarm threshold in m s x100 94 SW WIND DIRECTION ultrasonic anemometer lower alarm threshold i...

Page 13: ...59 B User code with ASCII codification of measurement 5 da 20060 a 20071 B User code with ASCII codification of measurement 6 da 20072 a 20083 B User code with ASCII codification of measurement 7 da 2...

Page 14: ...mples from 259 000 a 890 500 depending on the number of acquired quantities Interfaces ETHERNET RJ45 connector with proprietary TCP IP or Modbus TCP IP protocol USB mini USB connector Master RS485 Mod...

Page 15: ...the specific measures described in this operating manual The proper operation and the operational safety of the instrument can be ensured on ly under the climatic conditions specified in this manual...

Page 16: ...Server1 softwares downloadable from Delta OHM web site are included The probes and the CP23 USB cable have to be ordered separately The Ethernet cable is not included Accessories HD35AP CFR21 Software...

Page 17: ...HD50 17 V1 0 NOTES...

Page 18: ...HD50 18 V1 0 NOTES...

Page 19: ......

Page 20: ...ed third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic...

Reviews: