ISOLATED ANALOG  

 

SM15K INTERFACES 

17 / 19 

DELTA ELEKTRONIKA B.V. 

rev. Nov. 2019 

 

 

7

 

ISOLATED ANALOG INTERFACE 

 

Warning!

 carefully read the chapter "Safety Instructions" in 

this manual before connecting or operating the unit! 

7.1

 

CONDENSATION 

 

During normal operation, humidity will not harm the 
interfaces,  provided the air is not aggressive. The heat 
normally produced in the power supply will keep it dry. 

 

Avoid condensation inside the interfaces, to prevent break-
down. Condensation can occur during a period the power 
supply has been switched off (or operating at no load) and 
the ambient temperature is increasing. Always allow the 
power supply to dry before switching it on again. 

7.2

 

TEMPERATURE & COOLING 

 

The storage temperature range is 

–40 to +85 °C. 

 

The operating temperature range is 

–20 to +50 °C. But this 

temperature range only holds when the air-intake and air-
outlet of the power supply are unobstructed and the 
temperature of the air-intake is not higher than +50°C. 

 

When the power supply is mounted in a cabinet, please 
note that the temperature of the air-intake should be kept 
low and avoid a short circuit in the airflow i.e. the hot air 
leaving the air-outlet entering the air-intake again. 

 

Please note: a lower temperature extends the lifetime of the 
interface. 

7.3

 

FIRMWARE 

 

First install the interface inside the unit, then check the 
firmware package is P0120 or higher. In the front menu, go 
to: SYSTEM INFO -> UNIT-> VERSION. 

 

If an update is required, refer to the SM15K unit manual 
how to do this. 

7.4

 

HARDWARE INSTALLATION 

 

Warning!

 Never make connections to the Power Inputs 

and Outputs or the Sense Connector when the SM15K unit 
is connected to the mains supply or power outlet! 

 

Safety covers are used to cover these in- and outputs. 
 

7.4.1

 

INSERT INTERFACE IN THE UNIT 

 

Switch off the unit. 

 

Disconnect the unit from the mains supply. 

 

Wait for 3 minutes to allow internal circuits to discharge. 

 

Select a none used slot at the rear side.  
See figure 7 - 1. 

 

Unscrew the 2 torx T10 screws and remove the slot cover.  

 

Insert the interface and place the 2 screws back to secure 
the interface. 
 

7.4.2

 

CONNECT INTERFACE 

 

The connector on the analog interface is a female 15pole 
D-connector. 

 

Use cables with an internal wiring with a diameter of  
0.3 ... 0.5mm

2

 and with a sufficient voltage rating for the 

voltage of the circuit. 

 

To avoid hum or noise, the programming cable may have to 
be  twisted in some cases. 

 

With regards Safety, the analog programming connector is 
at the level of Protective Earth.  

 

Connect the cable to the programming source. 

 

The pinning of the INT MOD ANA is similar to other Delta 
Elektronika power supplies, see fig 7 - 2. 

 

Connect the mains supply again and check all the safety 
covers are installed. 

 

Switch on the unit. 

 

 

fig 7 - 1 

All positions are valid for INT MOD ANA. 

 

fig 7 - 3 

Position of the interface icon in the unit display. 

 

 

fig 7 - 2 

Pinning of the 15-pole programming connector. 

Summary of Contents for SM15K Series

Page 1: ...on P0120 Contents 1 Safety Instructions 2 Sicherheitshinweise 3 Master Slave Interface 4 Isolated Contacts 5 Serial Interface 6 Digital User I O 7 Isolated Analog Interface Firmware Update It is stron...

Page 2: ...nd either the minus or plus DC power terminal is grounded the voltage on the DC power terminals and sense connections can be considered safe Caution 1 If a low voltage unit has both DC power terminals...

Page 3: ...covers Safety cover s are used to cover potentially hazardous voltages Observe the following when removing safety cover s Switch off the unit Disconnect the unit from the mains supply or power outlet...

Page 4: ...als sicher angesehen werden wenn die minus DC Anschlussklemme des Ger ts im Verh ltnis zur Erdung 1000 VDC 707 Vpk nicht berschreitet f r SM70 CP 450 SM210 CP 150 und SM500 CP 90 oder 1500VDC 1060Vpk...

Page 5: ...ie Folgendes wenn Sie die Sicherheitsabdeckung en entfernen Ger t ausschalten Ger t von dem Versorgungsnetz oder der Stromquelle trennen Warten Sie 5 Minuten damit interne Kondensatoren sich entladen...

Page 6: ...er In the front menu go to SYSTEM INFO UNIT VERSION If an update is required refer to the SM15K unit manual how to do this 3 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs...

Page 7: ...first insert the bolts with crinkle washers in all DC power terminals Then assemble the entire strip to the DC power terminals This because bolts cannot be inserted in the DC power terminals once the...

Page 8: ...rip because it will burn out o Place the special M S parallel safety covers over the output terminals o Cover with marking DWG2532 is for the outputs of the upper and lower units Cover DWG2533 is for...

Page 9: ...own in the display see fig 3 6 The master or slave can also be configured via the web interface or using Ethernet commands After changing master or slave settings stored sequences need to be rebuilt d...

Page 10: ...how to do this 4 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to the mains supply or power outlet Safe...

Page 11: ...N M o 6 Relay 1 NC o 5 Relay 1 NO o 4 Relay 1 Common o 3 Relay 2 NC o 2 Relay 2 NO o 1 Relay 2 Common Pinning CON N o 6 Relay 3 NC o 5 Relay 3 NO o 4 Relay 3 Common o 3 Relay 4 NC o 2 Relay 4 NO o 1 R...

Page 12: ...to the SM15K unit manual how to do this 5 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to the mains su...

Page 13: ...e monitored Download the manual Ethernet Sequencer Programming SM15K for details 5 9 TROUBLE SHOOTING Check the programming source is set to the correct slot Check the output is switched ON the Interl...

Page 14: ...the unit must be in CC mode and when programming a power the unit must be in CP mode 5 10 CALIBRATION Calibration of the interface is not applicable 5 11 Settings Settings via the web page o Bus type...

Page 15: ...red refer to the SM15K unit manual how to do this 6 4 HARDWARE INSTALLATION Warning Never make connections to the Power Inputs and Outputs or the Sense Connector when the SM15K unit is connected to th...

Page 16: ...pin 15 The user inputs have a working range of 2V 30V use a common zero and have an impedance of approximately 22kOhms The maximum load of the 5V is 100mA See figure 6 4 and table 6 1 for the pinning...

Page 17: ...mware package is P0120 or higher In the front menu go to SYSTEM INFO UNIT VERSION If an update is required refer to the SM15K unit manual how to do this 7 4 HARDWARE INSTALLATION Warning Never make co...

Page 18: ...afe value Note that the programming inputs are floating with regards the power output Turn the output on again with the OUTPUT ON OFF button To program the unit by current instead of voltage simply us...

Page 19: ...ble to use a relay contact or a switch to shut the unit down see fig 7 9 In standby mode the power supply consumes very little power Note also via Eth or other interfaces RSD can be activated 7 10 REF...

Reviews: