Mechanical Dimension:
Unit: mm
DELTA ELECTRONICS, INC.
(TAOYUAN PLANT CPBG)
36
PFC4120V Series
Features
The PFC (Power Factor Corrector) chokes
is suitable for power supply. It is applied to
regulate the harmonics current and raise the
power factor.
Harmonics current regulation
Low leakage flux suitable for power supply
B
L
U
E
R
E
D
B
L
A
C
K
W
H
IT
E
39.0 Max.
95.0 5.0
110.0 5.0
24.0 Max.
12.5 Max.
45.0 Max.
62.5 Max.
52.5 0.5
16.5 Max.
44.5 Max.
4*6 0.5
4 0.5
SW
100V
230V
4
5
1
2
1
2
4
5
OUTPUT
INPUT LINE
o
AT 25 C, 60Hz/1V
PART NO.
INDUCTANCE (mH) Min.
DCR
( ) Max.
(reference)
INPUT POWER
o
RISE ( C) Max.
230V INPUT
Electrical Characteristics
TEMPERATURE
WITH FAN
100V INPUT
o
RISE ( C) Max.
TEMPERATURE
RATED CURRENT (Arms)
WITHOUT FAN
Recommended Circuit
100V INPUT
100V INPUT
RATED CURRENT (Arms)
230V INPUT
230V INPUT
PFC4120V01
21
98
3.8
195W
1.6
0.85
55
1.92
1.02
55
L2
L1
5 BLUE
4 RED
Schematic :
2 WHITE
1 BLACK
252, SAN YING ROAD, KUEISAN INDUSTRIAL ZONE, TAOYUAN SHIEN, 333, TAIWAN, R.O.C.
TEL: 886-3-3591968; FAX: 886-3-3591991
http://www.deltaww.com
for Power Supply