PCI-M324 User Guide EzDMC Functions
November, 2017
6-5
6
No.
Item
Description
(10)
Moving Mode
Check [Repeat] to repeatedly execute clockwise and
counterclockwise motions.
Check [S Curve] to set S-Curve acceleration /
deceleration; otherwise, T-Curve is used.
Check [Abs] to use absolute motion; otherwise, relative
motion is used.
(11)
A Move Reference
Command: absolute motion follows the command counter.
Encoder: absolute motion follows the feedback counter
position.
After opening the main screen, you need to set the relevant settings before executing motion
control.
Open the I/O related setting screen to set the signal logic, including ALM, INP, ELL, ORG, etc.
Click
Interface I/O Configuration
(Figure 6.4.3) on the M324 main screen to open the I/O
related setting screen (Figure 6.4.4).
Figure 6.4.3
Figure 6.4.4