Signal Connection Interface PCI-M324 User Guide
3-14
November, 2017
3
ERC (axis control signal / DO signal)
Error value clearing function: when the following conditions occur, PCI-M324 outputs an ERC
signal to the servo drive.
(1) PEL and MEL signals are triggered.
(2) EMG hardware circuit is triggered.
(3) Software EMG stop signal is triggered (API: _m324_emg_stop_erc).
(4) Force output ERC signal is triggered (API: _m324_set_erc_on).
(5) To follow the safety procedure, you must first clear the remaining command values in the
servo drive before starting the servo drive.
Pin
Mark
I/O
Description
Pin
Mark
I/O
Description
22
ERC_1
O
1
st
clear servo error
counter
72
ERC_3
O
3
rd
clear servo error
counter
26
ERC_2
O
2
nd
clear servo error
counter
76
ERC_4
O
4
th
clear servo error
counter
(1) O.C mode
EGND
ISO
I < 10 mA
N.O N.C
VCCID
Internal circuit
C
o
n
tro
lle
r
24V
EGND
OUT
24V
DC
Power supply
24V
0V